FabDigitFabDigit

Steel Permendur HR-ANN

Finish state

HR-ANN = hot-rolled / forged bar and billet, mill annealed

Bar, billet and ring stock for machined pole pieces, rotor hubs and magnetic-bearing parts; machine first, then final magnetic anneal.

High cost $$$$

Values for the HR-ANN condition

Other Permendur tempers and conditions

Permendur is listed in 4 conditions; see the grade overview at Permendur.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
MADefault
Magnetic final anneal
Standard delivered/finished condition for laminations, pole pieces and cores — gives full 2.3 T saturation and low coercivity, but the ordered structure is brittle so no forming afterwards.340520392 HRB—
HR-ANNThis page
Hot-rolled / forged bar and billet, mill annealed
Bar, billet and ring stock for machined pole pieces, rotor hubs and magnetic-bearing parts; machine first, then final magnetic anneal.3605605200 HB4.3 % IACS
Rapid-cooled (disordered) ductile condition, ~750–800 °C water/oil…
Choose when the part must be deep-drawn, bent or heavily machined: quenching suppresses B2 ordering and restores ductility; a final magnetic anneal is still required.40062015172 HB3.8 % IACS
Cold rolled
The normal purchase condition for stamping stock: hard, dimensionally stable strip that is blanked/etched first and magnetically annealed afterwards.720900230 HRC4.1 % IACS

What is Permendur HR-ANN?

Permendur HR-ANN is Permendur supplied in the HR-ANN condition — bar, billet and ring stock for machined pole pieces, rotor hubs and magnetic-bearing parts; machine first, then final magnetic anneal. Permendur HR-ANN has a yield strength of 360 MPa (52.2 ksi) and a tensile strength of 560 MPa (81.2 ksi) — weaker than 72% of steel grades. Elongation at break is 5% and the elastic modulus is 207 GPa (30 Msi). Permendur HR-ANN has a density of 8.12 g/cm³ (0.293 lb/in³), heavier than 97% of steel grades. It melts at 1,440°C (2,624 °F). MA is the default condition FabDigit quotes; HR-ANN is available on request or by drawing note.

Advantages

  • High service temperature — 500°C (932 °F), better than 90% of steel grades
  • Good corrosion resistance — 22/100, better than 90% of steel grades
  • Polishes to a fine finish — 65/100, better than 78% of steel grades

Limitations

  • High embodied carbon — 7.5 kg CO₂/kg, worse than 99% of steel grades
  • Limited ductility — 5%, worse than 98% of steel grades
  • Difficult to machine — 25/100, worse than 93% of steel grades
  • Limited formability — 15/100, worse than 87% of steel grades
  • Poor heat conductor — 29.8 W/m·K (17.2 BTU/hr·ft·°F), worse than 84% of steel grades

Permendur HR-ANN properties

Typical room-temperature values for Permendur HR-ANN; 22 are specific to this condition. Other listed values are Permendur reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

Permendur HR-ANN has a density of 8.12 g/cm³ (0.293 lb/in³), heavier than 97% of steel grades. It melts at 1,440°C (2,624 °F).

Density8.12 g/cm³0.29 lb/in³
Melting Point (Solidus)1,440°C2,624 °F
Liquidus Temperature1,490°C2,714 °F

Mechanical14

Permendur HR-ANN has a yield strength of 360 MPa (52.2 ksi) and a tensile strength of 560 MPa (81.2 ksi) — weaker than 72% of steel grades. Elongation at break is 5% and the elastic modulus is 207 GPa (30 Msi).

Elastic (Young's) Modulus207 GPa30 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus165 GPa23.9 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)560 MPa81.2 ksi
Yield Strength (0.2% offset)360 MPa52.2 ksi
Elongation at Break5%
Reduction in Area8%
Shear Strength400 MPa58 ksi
Fatigue Strength (Endurance Limit)260 MPa37.7 ksi
Charpy V-Notch Impact (RT)10 J7.4 ft·lbf
Hardness, Brinell200 HB
Hardness, Rockwell B93 HRB
Hardness, Vickers210 HV

Thermal6

Permendur HR-ANN is rated for continuous service to 500°C (932 °F). It conducts heat at 29.8 W/m·K (17.2 BTU/hr·ft·°F), worse than 84% of steel grades. Thermal expansion is 9.6 µm/m·K (5.33 µin/in·°F).

Thermal Conductivity29.8 W/m·K17.2 BTU/hr·ft·°F
Specific Heat Capacity420 J/kg·K0.1 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)9.6 µm/m·K5.3 µin/in·°F
Latent Heat of Fusion250 J/g107 BTU/lb
Max Service Temperature (continuous)500°C932 °F
Min Service Temperature-196°C-321 °F

Electrical3

Permendur HR-ANN conducts electricity at 4.3 % IACS, worse than 82% of steel grades.

Electrical Conductivity4.3 % IACS
Electrical Resistivity4×10⁻⁷ Ω·m15.7 µΩ·in
Magnetic Responseferromagnetic — Bs ≈ 2.3–2.4 T, Hc ≈ 40–120 A/m, µmax ≈ 6,000–12,000

Chemical & Environmental3

Corrosion resistance is poor (22/100), better than 90% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.5 V
Corrosion ResistancePoor22/100
Chemical Resistance SummaryRusts in humid air and is attacked by dilute acids and chlorides; cobalt leaches in acidic media. Requires nickel/tin plating, phosphating, oxide or organic coating; laminations are usually oxide- or resin-insulated after anneal.

Sustainability4

Producing a kilogram of Permendur HR-ANN takes about 95 MJ of energy and emits 7.5 kg of CO₂ — more than 99% of steel grades. Typical recycled content is 25%.

Embodied Energy (primary production)95 MJ/kg40,843 BTU/lb
Embodied Carbon (primary production)7.5 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content25%

Manufacturability8

Permendur HR-ANN's machinability is poor (25/100, worse than 93% of steel grades); weldability fair (40/100); formability poor (15/100).

MachinabilityPoor25/100
Machinability Rating (AISI 1212 = 100 %)22%
WeldabilityFair40/100
Formability (cold)Poor15/100
CastabilityPoor30/100
Brazeability / SolderabilityGood55/100
PolishabilityGood65/100
Anodizing Responsen/a — ferrous alloy; protect by electroless Ni, Ni/Sn plating, phosphate or inorganic lamination coating instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Permendur HR-ANN

Is Permendur easy to machine?

Machine in the as-rolled or quenched-disordered state with sharp carbide tooling, rigid setups, low speed and flood coolant — the ordered annealed material chips and cracks; finish-machine before the final magnetic anneal.

Can Permendur be welded?

GTAW, laser and electron-beam welding are feasible with matching or Fe-Co filler and preheat; welds must be re-annealed in dry hydrogen to restore permeability, and weld zones stay locally hard and crack-prone.

Can Permendur be formed, bent or molded?

Blank, stamp, etch or draw in the hard as-rolled or quenched condition; never bend after the ordering anneal, and stress-relieve/final-anneal parts at 840–885 °C in dry H₂ with a slow (≤150 °C/h) cool.

What surface finishes work on Permendur?

No inherent corrosion resistance — apply electroless nickel, Ni/Sn plating, phosphate or an inorganic C-5-type lamination coating; pole faces polish well but must be protected against humid-air rusting.

Permendur chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cogives the 2.3 T saturation48.5 – 5049
Vraises resistivity and workability, suppresses ordering embrittlement1.4 – 2.22
Ckept low for low coercivity≤ 0.030.01
Mn≤ 0.30.05
Si≤ 0.30.05
Niresidual≤ 0.50.1
S≤ 0.020.01
P≤ 0.020.01
Febalance, ~49 %balance—

Permendur HR-ANN — frequently asked

What is Permendur HR-ANN used for?

Permendur HR-ANN is typically used for aerospace generator/motor laminations, magnetic pole pieces, high-flux transformer cores and electromagnet pole tips. In short: highest saturation soft-magnetic alloy; highest service temperature here; brittle after ordering anneal.

What is the yield strength of Permendur HR-ANN?

Permendur HR-ANN has a typical yield strength of 360 MPa (52.2 ksi) and a tensile strength of 560 MPa (81.2 ksi) — weaker than 72% of steel grades. Strength varies by condition: see the 4 listed tempers.

Is Permendur HR-ANN easy to machine?

Not especially — machinability is rated poor (25/100, worse than 93% of steel grades). Machine in the as-rolled or quenched-disordered state with sharp carbide tooling, rigid setups, low speed and flood coolant — the ordered annealed material chips and cracks; finish-machine before the final magnetic anneal.

Can Permendur HR-ANN be welded?

With care — weldability is rated fair (40/100). GTAW, laser and electron-beam welding are feasible with matching or Fe-Co filler and preheat; welds must be re-annealed in dry hydrogen to restore permeability, and weld zones stay locally hard and crack-prone.

What surface finishes work on Permendur HR-ANN?

No inherent corrosion resistance — apply electroless nickel, Ni/Sn plating, phosphate or an inorganic C-5-type lamination coating; pole faces polish well but must be protected against humid-air rusting.

Can Permendur HR-ANN be formed, bent or molded?

Blank, stamp, etch or draw in the hard as-rolled or quenched condition; never bend after the ordering anneal, and stress-relieve/final-anneal parts at 840–885 °C in dry H₂ with a slow (≤150 °C/h) cool.

What is the maximum service temperature of Permendur HR-ANN?

Permendur HR-ANN is rated for continuous use to about 500°C (932 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Permendur-MA and Permendur-CR?

MA is the default condition — standard delivered/finished condition for laminations, pole pieces and cores — gives full 2.3 T saturation and low coercivity, but the ordered structure is brittle so no forming afterwards. CR: the normal purchase condition for stamping stock: hard, dimensionally stable strip that is blanked/etched first and magnetically annealed afterwards. Yield strength is 340 MPa in MA versus 720 MPa in CR.

Sources

  1. Hiperco 50 Alloy technical datasheet — Carpenter Technology (2020)
  2. VACOFLUX 50 soft magnetic cobalt-iron alloy — Vacuumschmelze (2021)
  3. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials (Soft Magnetic Materials) — ASM International (1990)
  4. ASTM A801 — Standard Specification for Wrought Iron-Cobalt High Magnetic Saturation Alloys — ASTM (2021)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.