FabDigitFabDigit

Technora T200

Grade · default condition

T200 = standard filament yarn

Default high-tenacity filament yarn for ropes, cables, optical-cable strength members and composite reinforcement.

High cost $$$$

Values for the T200 condition

Other Technora grades and fills

Technora is listed in 4 conditions; see the grade overview at Technora.

Compare all 4 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Rubber-reinforcement grade / dipped cord base
Use for RFL-dipped cords in high-pressure hose, timing/power-transmission belts and tire reinforcement where flex fatigue dominates.—3,0004.8—
Short-cut / chopped fiber (1–12 mm)
Use as reinforcement/anti-squeal additive in friction materials, gaskets, sealants, cement and thermoplastic compounds.—3,0004.4—
Adhesive-activated yarn for rubber/resin bonding
Pick when the yarn must bond to rubber or resin (hose, belt, tire) without a separate epoxy pre-treatment.—3,2004.5—
T200DefaultThis page
Standard filament yarn
Default high-tenacity filament yarn for ropes, cables, optical-cable strength members and composite reinforcement.—3,4004.4—

What is Technora T200?

Technora T200 is Technora in the T200 grade — default high-tenacity filament yarn for ropes, cables, optical-cable strength members and composite reinforcement. Technora T200 has a tensile strength of 3,400 MPa (493 ksi), stronger than 85% of composite grades. Elongation at break is 4.4% and the elastic modulus is 72 GPa (10.4 Msi). Technora T200 has a density of 1.39 g/cm³ (0.0502 lb/in³), lighter than 66% of composite grades. Its glass-transition temperature is 300°C (572 °F).

Advantages

  • Ductile — tolerates forming and impact — 4.4%, better than 84% of composite grades

Limitations

  • Absorbs moisture — dry before molding — 2%, worse than 88% of composite grades
  • Poor heat conductor — 0.05 W/m·K (0.0289 BTU/hr·ft·°F), worse than 87% of composite grades
  • Degrades in UV without stabilisers — 25/100, worse than 86% of composite grades
  • Difficult to machine — 20/100, worse than 77% of composite grades

Technora T200 properties

Typical room-temperature values for Technora T200; 11 are specific to this condition. Other listed values are Technora reference data and may not represent this condition. Bars are the position among composite grades.

Physical4

Technora T200 has a density of 1.39 g/cm³ (0.0502 lb/in³), lighter than 66% of composite grades. Its glass-transition temperature is 300°C (572 °F).

Density1.39 g/cm³0.05 lb/in³
Glass Transition (Tg)300°C572 °F
Water Absorption (24 h)2%
Water Absorption (Saturation)3%

Mechanical6

Technora T200 has a tensile strength of 3,400 MPa (493 ksi), stronger than 85% of composite grades. Elongation at break is 4.4% and the elastic modulus is 72 GPa (10.4 Msi).

Elastic (Young's) Modulus72 GPa10.4 Msi
Poisson's Ratio0.35
Tensile Strength (Ultimate)3,400 MPa493 ksi
Elongation at Break4.4%
Compressive Strength350 MPa50.8 ksi
Shear Strength50 MPa7.3 ksi

Thermal8

Technora T200 is rated for continuous service to 200°C (392 °F). It conducts heat at 0.05 W/m·K (0.0289 BTU/hr·ft·°F), worse than 87% of composite grades. Thermal expansion is -3 µm/m·K (-1.67 µin/in·°F).

Thermal Conductivity0.05 W/m·K0.03 BTU/hr·ft·°F
Specific Heat Capacity1,420 J/kg·K0.34 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)-3 µm/m·K-1.7 µin/in·°F
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-70°C-94 °F
Flammability (UL 94)Inherently flame-resistant, self-extinguishing; does not melt or drip (fiber form, not a molded UL 94 bar)
Limiting Oxygen Index25%
Max Service Temperature (short-term)300°C572 °F

Electrical3

Technora T200 has an electrical resistivity of 1×10¹² Ω·m.

Electrical Resistivity1×10¹² Ω·m3.94×10¹⁹ µΩ·in
Dielectric Constant (1 MHz)3.8
Volume Resistivity1×10¹⁴ Ω·cm

Chemical & Environmental3

Corrosion resistance is very good (80/100), better than 54% of composite grades. UV resistance is poor.

Corrosion ResistanceVery good80/100
UV / Weathering ResistancePoor25/100
Chemical Resistance SummaryMarkedly better acid, alkali and hydrolysis resistance than homopolymer para-aramid; good against most organic solvents, oils, fuels and steam; attacked by strong oxidizers, hot concentrated sulfuric/nitric acid and prolonged UV exposure.

Sustainability4

Producing a kilogram of Technora T200 takes about 260 MJ of energy and emits 15 kg of CO₂ — more than 57% of composite grades. Typical recycled content is 0%.

Embodied Energy (primary production)260 MJ/kg111,780 BTU/lb
Embodied Carbon (primary production)15 kg CO₂/kg
Embodied Water400 L/kg47.9 gal/lb
Typical Recycled Content0%

Manufacturability1

Technora T200's machinability is poor (20/100, worse than 77% of composite grades).

MachinabilityPoor20/100

Common Calculations4

Specific Strength (UTS / density)calculated2,446 kN·m/kg
Specific Stiffness (E / density)calculated51.8 MN·m/kg
Thermal Diffusivitycalculated0 mm²/s
Thermal Shock Resistance Indexcalculated-1

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Technora T200

Is Technora easy to machine?

Cutting fuzzes badly — use hot knife, ultrasonic or laser for fabric, and PCD/serrated or compression-router tooling with sharp positive rake for cured laminates; expect no melting, only charring.

Can Technora be welded?

Not weldable or fusible (decomposes ~500 °C without melting); join by stitching, splicing, mechanical termination or adhesive/resin bonding.

Can Technora be formed, bent or molded?

Processed as yarn, cord, woven/UD fabric or short-cut fiber into thermoset (epoxy, phenolic, vinyl ester) or rubber matrices; low compression strength means avoid fiber-direction compressive loading and consider hybridizing with carbon or glass.

What surface finishes work on Technora?

Use RFL/epoxy dip or adhesive-activated grade (T221/T240) for rubber and resin adhesion; protect from sunlight with pigmented jackets, coatings or overbraids because UV strength loss is rapid.

Technora chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
terephthaloyl chloride (terephthalamide mol % of monomer feed; acid chloride component48 – 5250
p-phenylenediamine (PPD)mol %; rigid para unit20 – 3025
3,4'-diaminodiphenyl ether (3,4'-ODA)mol %; co-monomer giving the copolymer its higher elongation and hydrolysis resistance20 – 3025
finish / spin oilsurface finish on filament yarn (wt %)0.2 – 1.50.5

Technora T200 — frequently asked

What is Technora T200 used for?

Technora T200 is typically used for submarine cables, optical fiber cable strength members, tire cords and ropes. In short: highest-elongation para-aramid; best aramid fatigue resistance; adhesive-activated yarn grades.

What is the tensile strength of Technora T200?

Technora T200 has a typical tensile strength of 3,400 MPa (493 ksi) — stronger than 85% of composite grades. Strength varies by condition: see the 4 listed tempers.

Is Technora T200 easy to machine?

Not especially — machinability is rated poor (20/100, worse than 77% of composite grades). Cutting fuzzes badly — use hot knife, ultrasonic or laser for fabric, and PCD/serrated or compression-router tooling with sharp positive rake for cured laminates; expect no melting, only charring.

Can Technora T200 be welded?

Not weldable or fusible (decomposes ~500 °C without melting); join by stitching, splicing, mechanical termination or adhesive/resin bonding.

What surface finishes work on Technora T200?

Use RFL/epoxy dip or adhesive-activated grade (T221/T240) for rubber and resin adhesion; protect from sunlight with pigmented jackets, coatings or overbraids because UV strength loss is rapid.

Can Technora T200 be formed, bent or molded?

Processed as yarn, cord, woven/UD fabric or short-cut fiber into thermoset (epoxy, phenolic, vinyl ester) or rubber matrices; low compression strength means avoid fiber-direction compressive loading and consider hybridizing with carbon or glass.

What is the maximum service temperature of Technora T200?

Technora T200 is rated for continuous use to about 200°C (392 °F), and briefly to 300°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Technora Para-aramid Fiber — Technical Information — Teijin Aramid / Teijin Limited (2023)
  2. High-Performance Fibres (ed. J. W. S. Hearle) — aramid chapter — Woodhead Publishing (2001)
  3. ASM Handbook Vol. 21: Composites — aramid fiber reinforcements — ASM International (2001)
  4. CES/Granta generic aramid fiber records (LCA and mechanical ranges) — Ansys Granta (2022)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.