FabDigitFabDigit

Kevlar 49 vs Technora

Composite · grade comparison

Kevlar 49 and Technora are both composite grades. Technora is the stronger of the two: tensile strength 3,400 MPa (493 ksi) against 3,000 MPa (435 ksi) for Kevlar 49, about 13% more. Technora is the more ductile: elongation 4.4% versus 2.4% for Kevlar 49. Technora is lighter (1.39 g/cm³ vs 1.44 g/cm³ for Kevlar 49) and Kevlar 49 is stiffer (112 GPa vs 72 GPa).

TechnoraChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

Kevlar 49 vs Technora: properties

Kevlar 49Technora

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

112 GPa16.2 Msi
72 GPa10.4 Msi

Shear Modulus

2.9 GPa0.42 Msi
—

Poisson's Ratio

0.36
0.35

Tensile Strength (Ultimate)

3,000 MPa435 ksi
3,400 MPa493 ksi

Elongation at Break

2.4%
4.4%

Compressive Strength

—
350 MPa50.8 ksi

Shear Strength

—
50 MPa7.3 ksi

Physical

Density and transition temperatures.

Density

1.44 g/cm³0.05 lb/in³
1.39 g/cm³0.05 lb/in³

Glass Transition (Tg)

360°C680 °F
300°C572 °F

Water Absorption (Saturation)

4%
3%

Water Absorption (24 h)

—
2%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.04 W/m·K0.02 BTU/hr·ft·°F
0.05 W/m·K0.03 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

-2 µm/m·K-1.1 µin/in·°F
-3 µm/m·K-1.7 µin/in·°F

Max Service Temperature (continuous)

160°C320 °F
200°C392 °F

Min Service Temperature

-196°C-321 °F
-70°C-94 °F

Limiting Oxygen Index

29%
25%

Max Service Temperature (short-term)

250°C482 °F
300°C572 °F

Same in both: Specific Heat Capacity 1,420 J/kg·K0.34 BTU/lb·°F

Electrical

Conductivity and insulation.

Electrical Resistivity

1×10¹³ Ω·m3.94×10²⁰ µΩ·in
1×10¹² Ω·m3.94×10¹⁹ µΩ·in

Dielectric Constant (1 MHz)

4
3.8

Dissipation Factor (1 MHz)

0.02
—

Volume Resistivity

1×10¹⁵ Ω·cm
1×10¹⁴ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
80 / 100

UV / Weathering Resistance

20 / 100
25 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
20 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

280 MJ/kg120,378 BTU/lb
260 MJ/kg111,780 BTU/lb

Embodied Carbon (primary production)

17 kg CO₂/kg
15 kg CO₂/kg

Embodied Water

—
400 L/kg47.9 gal/lb

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

2,083 kN·m/kg
2,446 kN·m/kg

Specific Stiffness (E / density)

77.8 MN·m/kg
51.8 MN·m/kg

Same in both: Thermal Diffusivity 0 mm²/s · Thermal Shock Resistance Index -1

Strength versus weight

Yield strength against density for every composite grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1101001,000510Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityKevlar 49Technora
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Kevlar 49 vs Technora — frequently asked

Is Technora stronger than Kevlar 49?

Yes. Technora has a typical tensile strength of 3,400 MPa (493 ksi) against 3,000 MPa (435 ksi) for Kevlar 49 — about 13% more.

Which is cheaper, Kevlar 49 or Technora?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, Kevlar 49 or Technora?

Kevlar 49, by a small margin. Both rate poor for machinability — 25/100 against 20/100 for Technora.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Kevlar 49 and Technora side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.