FabDigitFabDigit

IIR A50

Hardness band

ASTM CIIR, BIIR

A50 = shore A 50

General static seals and pharmaceutical stoppers needing needle penetration and reseal.

Standard cost $$

Values for the A50 condition

Other IIR grades and fills

IIR is listed in 10 conditions; see the grade overview at IIR.

Compare all 10 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Closed-cell butyl sponge / foam
Low-density compressible weather and acoustic sealing with very low water/vapour transmission.—120015 Shore A
Shore A 40
Soft gaskets, damping pads and low-clamp-force seals.—875040 Shore A
Electrical insulation grade
Cable insulation, splicing tape and mastics where high resistivity plus moisture barrier are required.—955012 Shore D
A50This page
Shore A 50
General static seals and pharmaceutical stoppers needing needle penetration and reseal.—1068050 Shore A
IIR-GPDefault
IIR general purpose
Standard butyl compound for inner tubes, vibration damping, weather seals and waterproof sheet.—1260060 Shore A
Chlorobutyl (≈1.2 % Cl), fast/versatile cure, blendable with NR/SBR
Pick when butyl must be co-vulcanized or bonded to diene rubbers, e.g. tire inner liners and tubeless liners.—1260060 Shore A
Bromobutyl (≈2 % Br), fastest cure, best liner impermeability and…
Choose for tubeless tire inner liners and premium pharmaceutical closures needing fast, low-extractable cure.—1360060 Shore A
phenolic resin vulcanization, heat/steam resistant (curing bladders)
Use for tire curing bladders, steam hose and diaphragms exposed to superheated steam above 150 °C.—1350060 Shore A
Shore A 70
Default hardness for O-rings and pressure-holding seals in brake fluid or steam service.—1345022 Shore D
Shore A 80
High-pressure seals, rollers and abrasion/extrusion-resistant parts.—1433030 Shore D

What is IIR A50?

IIR A50 is IIR heat treated to A50 — general static seals and pharmaceutical stoppers needing needle penetration and reseal. IIR A50 has a tensile strength of 10 MPa (1.45 ksi), weaker than 79% of polymer grades. Elongation at break is 680% and the elastic modulus is 0 GPa (4.06×10⁻⁴ Msi). IIR A50 has a density of 1.1 g/cm³ (0.0397 lb/in³), lighter than 66% of polymer grades. Its glass-transition temperature is -68°C (-90 °F). IIR-GP is the default condition FabDigit quotes; A50 is available on request or by drawing note.

Advantages

  • Ductile — tolerates forming and impact — 680%, better than 95% of polymer grades
  • Good UV / weathering resistance — 80/100, better than 86% of polymer grades
  • Forms and bends easily — 85/100, better than 81% of polymer grades

Limitations

  • High mold shrinkage — 2.8%, worse than 96% of polymer grades
  • Low stiffness — 0 GPa (4.06×10⁻⁴ Msi), worse than 93% of polymer grades
  • Difficult to machine — 25/100, worse than 93% of polymer grades
  • Difficult to weld — 5/100, worse than 89% of polymer grades
  • Poor heat conductor — 0.12 W/m·K (0.0693 BTU/hr·ft·°F), worse than 83% of polymer grades

IIR A50 properties

Typical room-temperature values for IIR A50; 16 are specific to this condition. Other listed values are IIR reference data and may not represent this condition. Bars are the position among polymer grades.

Physical3

IIR A50 has a density of 1.1 g/cm³ (0.0397 lb/in³), lighter than 66% of polymer grades. Its glass-transition temperature is -68°C (-90 °F).

Density1.1 g/cm³0.04 lb/in³
Glass Transition (Tg)-68°C-90 °F
Water Absorption (24 h)0.5%

Mechanical7

IIR A50 has a tensile strength of 10 MPa (1.45 ksi), weaker than 79% of polymer grades. Elongation at break is 680% and the elastic modulus is 0 GPa (4.06×10⁻⁴ Msi).

Elastic (Young's) Modulus0 GPa4.06×10⁻⁴ Msi
Poisson's Ratio0.49
Tensile Strength (Ultimate)10 MPa1.5 ksi
Elongation at Break680%
Hardness, Shore A50 Shore A
Tear Strength25 kN/m143 lbf/in
Compression Set (22 h, 70 °C)37%

Thermal8

IIR A50 is rated for continuous service to 125°C (257 °F). It conducts heat at 0.12 W/m·K (0.0693 BTU/hr·ft·°F), worse than 83% of polymer grades. Thermal expansion is 180 µm/m·K (100 µin/in·°F).

Thermal Conductivity0.12 W/m·K0.07 BTU/hr·ft·°F
Specific Heat Capacity1,900 J/kg·K0.45 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)180 µm/m·K100 µin/in·°F
Max Service Temperature (continuous)125°C257 °F
Min Service Temperature-50°C-58 °F
Flammability (UL 94)HB — burns slowly, not self-extinguishing without flame-retardant loading
Limiting Oxygen Index20%
Max Service Temperature (short-term)165°C329 °F

Electrical5

IIR A50 is an electrical insulator with a dielectric strength of 25 kV/mm (635 V/mil) and a resistivity of 1×10¹² Ω·m.

Electrical Resistivity1×10¹² Ω·m3.94×10¹⁹ µΩ·in
Dielectric Strength25 kV/mm635 V/mil
Dielectric Constant (1 MHz)2.3
Dissipation Factor (1 MHz)0.003
Volume Resistivity1×10¹⁵ Ω·cm

Chemical & Environmental3

Corrosion resistance is very good (75/100), worse than 66% of polymer grades. UV resistance is very good.

Corrosion ResistanceVery good75/100
UV / Weathering ResistanceVery good80/100
Chemical Resistance SummaryExcellent in water, steam, acids, alkalis, alcohols, ketones, glycol brake fluid and phosphate-ester hydraulic fluids; outstanding ozone/weathering; poor in mineral oils, fuels, aromatic and chlorinated hydrocarbons (swells badly).

Sustainability4

Producing a kilogram of IIR A50 takes about 105 MJ of energy and emits 4 kg of CO₂ — more than 54% of polymer grades. Typical recycled content is 5%.

Embodied Energy (primary production)105 MJ/kg45,142 BTU/lb
Embodied Carbon (primary production)4 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content5%

Manufacturability6

IIR A50's machinability is poor (25/100, worse than 93% of polymer grades); weldability not recommended (5/100); formability excellent (85/100).

MachinabilityPoor25/100
WeldabilityNot recommended5/100
Formability (cold)Excellent85/100
Mold Shrinkage2.8%
Processing Melt Temperature (typ.)90°C194 °F
Mold Temperature (typ.)175°C347 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with IIR A50

Is IIR easy to machine?

Cured butyl is not machined conventionally — use die cutting, water-jet or cryogenic trimming; grinding smears and heats the part.

Can IIR be welded?

Not weldable as a thermoset; join by uncured-to-uncured co-vulcanization, butyl splicing tape/mastic, or cyanoacrylate/chlorinated-surface adhesives after abrasion.

Can IIR be formed, bent or molded?

Mix on mill/Banbury below scorch, then compression, transfer or injection mould at 160–190 °C; halobutyl cures much faster and bonds better to NR/SBR carcasses.

What surface finishes work on IIR?

Deflash by cryogenic tumbling; surfaces can be talc- or lacquer-coated, chlorinated or plasma-treated for lower friction and for bonding/printing.

IIR chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
isopreneunsaturation for sulfur cure; often quoted as 0.6–2.2 mol %0.5 – 31.7
chlorineCIIR (chlorobutyl) variant only1.1 – 1.31.2
bromineBIIR (bromobutyl) variant only1.8 – 2.12
carbon blacktypical compound loading 40–60 phr (≈25–35 wt %)≈ 3030
processing oil / plasticizerparaffinic oil in the compound≈ 88
zinc oxide / stearic acid / sulfur / acccure system≈ 44
isobutylenepolymer backbone (2-methylpropene)≥ 97 (balance)—

IIR A50 — frequently asked

What is IIR A50 used for?

IIR A50 is typically used for tire inner liners, pharma vial stoppers, vibration dampers and roofing. In short: lowest gas permeability elastomer; high damping, steam resistant; standard pharma closure rubber.

What is the tensile strength of IIR A50?

IIR A50 has a typical tensile strength of 10 MPa (1.45 ksi) — weaker than 79% of polymer grades. Strength varies by condition: see the 10 listed tempers.

Is IIR A50 easy to machine?

Not especially — machinability is rated poor (25/100, worse than 93% of polymer grades). Cured butyl is not machined conventionally — use die cutting, water-jet or cryogenic trimming; grinding smears and heats the part.

Can IIR A50 be welded?

Not readily — weldability is rated not recommended (5/100). Not weldable as a thermoset; join by uncured-to-uncured co-vulcanization, butyl splicing tape/mastic, or cyanoacrylate/chlorinated-surface adhesives after abrasion.

What surface finishes work on IIR A50?

Deflash by cryogenic tumbling; surfaces can be talc- or lacquer-coated, chlorinated or plasma-treated for lower friction and for bonding/printing.

Can IIR A50 be formed, bent or molded?

Mix on mill/Banbury below scorch, then compression, transfer or injection mould at 160–190 °C; halobutyl cures much faster and bonds better to NR/SBR carcasses.

What is the maximum service temperature of IIR A50?

IIR A50 is rated for continuous use to about 125°C (257 °F), and briefly to 165°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Butyl and Halobutyl Rubber Product Data (Exxon Butyl / Bromobutyl) — ExxonMobil Chemical (2021)
  2. Engineered Materials Handbook Vol. 2 — Engineering Plastics/Elastomers — ASM International (1988)
  3. ASTM D2000 — Classification System for Rubber Products in Automotive Applications — ASTM (2020)
  4. GB/T 8657 (IIR) — SAC (2018)
  5. ISO 8871 — Elastomeric parts for parenterals — ISO (2020)
  6. Rubber Technology Handbook (Hofmann) / Vanderbilt Rubber Handbook — Hanser / R.T. Vanderbilt (2010)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.