FabDigitFabDigit

Steel Custom 455-H1050

Precip hard

UNS S45500 · AISI/SAE XM-16 · ASTM A564

H1050 = aged 4 h at 565 °C

Over-aged, toughest condition — choose where ductility, notch toughness and SCC resistance matter more than peak strength.

High cost $$$$

Values for the H1050 condition

Other Custom 455 tempers and conditions

Custom 455 is listed in 6 conditions; see the grade overview at Custom 455.

Compare all 6 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Solution annealed
Pick for machining, cold forming, heading or welding before a single low-temperature aging cycle.7951,0001431 HRC—
Condition A, cold drawn bar/wire
Cold-drawn solution-annealed wire and bar for cold-headed fasteners and springs, aged after forming.1,0301,170836 HRC2.2 % IACS
H1050This page
Aged 4 h at 565 °C
Over-aged, toughest condition — choose where ductility, notch toughness and SCC resistance matter more than peak strength.1,3801,4501443 HRC—
H1000Default
Aged 4 h at 540 °C
Most commonly stocked aged condition — ~225 ksi with the best strength/toughness and stress-corrosion balance.1,4501,5501246 HRC—
Aged 4 h at 510 °C
Standard A564 aerospace fastener condition: ~240 ksi strength with slightly better ductility than H900.1,5801,6551148 HRC—
Aged 482 °C (900 °F) for 1 h, peak hardness
Highest strength/hardness condition — use for peak-strength fasteners and pins where toughness demand is modest.1,6201,7201049 HRC—

What is Custom 455-H1050?

Custom 455-H1050 is Custom 455 in the H1050 condition — over-aged, toughest condition — choose where ductility, notch toughness and SCC resistance matter more than peak strength. Custom 455-H1050 has a yield strength of 1,380 MPa (200 ksi) and a tensile strength of 1,450 MPa (210 ksi) — stronger than 96% of steel grades. Elongation at break is 14% and the elastic modulus is 200 GPa (29 Msi). Custom 455-H1050 has a density of 7.76 g/cm³ (0.28 lb/in³), lighter than 92% of steel grades. It melts at 1,400°C (2,552 °F). H1000 is the default condition FabDigit quotes; H1050 is available on request or by drawing note.

Advantages

  • Good corrosion resistance — 57/100, better than 99% of steel grades
  • Polishes to a fine finish — 80/100, better than 97% of steel grades
  • High strength — 1,380 MPa (200 ksi), better than 96% of steel grades
  • High service temperature — 450°C (842 °F), better than 86% of steel grades

Limitations

  • Poor heat conductor — 17.6 W/m·K (10.2 BTU/hr·ft·°F), worse than 98% of steel grades
  • Low electrical conductivity — 2.2 % IACS, worse than 98% of steel grades
  • High embodied carbon — 5.2 kg CO₂/kg, worse than 96% of steel grades
  • Difficult to machine — 28/100, worse than 91% of steel grades
  • Limited ductility — 14%, worse than 75% of steel grades

Custom 455-H1050 properties

Typical room-temperature values for Custom 455-H1050; 16 are specific to this condition. Other listed values are Custom 455 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

Custom 455-H1050 has a density of 7.76 g/cm³ (0.28 lb/in³), lighter than 92% of steel grades. It melts at 1,400°C (2,552 °F).

Density7.76 g/cm³0.28 lb/in³
Melting Point (Solidus)1,400°C2,552 °F
Liquidus Temperature1,450°C2,642 °F

Mechanical16

Custom 455-H1050 has a yield strength of 1,380 MPa (200 ksi) and a tensile strength of 1,450 MPa (210 ksi) — stronger than 96% of steel grades. Elongation at break is 14% and the elastic modulus is 200 GPa (29 Msi).

Elastic (Young's) Modulus200 GPa29 Msi
Shear Modulus77 GPa11.2 Msi
Bulk Modulus166 GPa24.1 Msi
Poisson's Ratio0.3
Tensile Strength (Ultimate)1,450 MPa210 ksi
Yield Strength (0.2% offset)1,380 MPa200 ksi
Elongation at Break14%
Reduction in Area50%
Compressive Strength1,500 MPa218 ksi
Shear Strength870 MPa126 ksi
Fatigue Strength (Endurance Limit)690 MPa100 ksi
Fracture Toughness (K_IC)95 MPa·√m86.5 ksi·√in
Charpy V-Notch Impact (RT)34 J25.1 ft·lbf
Hardness, Brinell400 HB
Hardness, Rockwell C43 HRC
Hardness, Vickers420 HV

Thermal6

Custom 455-H1050 is rated for continuous service to 450°C (842 °F). It conducts heat at 17.6 W/m·K (10.2 BTU/hr·ft·°F), worse than 98% of steel grades. Thermal expansion is 10.2 µm/m·K (5.67 µin/in·°F).

Thermal Conductivity17.6 W/m·K10.2 BTU/hr·ft·°F
Specific Heat Capacity460 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)10.2 µm/m·K5.7 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)450°C842 °F
Min Service Temperature-73°C-99 °F

Electrical3

Custom 455-H1050 conducts electricity at 2.2 % IACS, worse than 98% of steel grades.

Electrical Conductivity2.2 % IACS
Electrical Resistivity8×10⁻⁷ Ω·m31.5 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is good (57/100), better than 99% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.25 V
Corrosion ResistanceGood57/100
Chemical Resistance SummaryPassive in atmosphere, fresh water and mild industrial media, comparable to 17-4PH; susceptible to pitting in chlorides/seawater and to hydrogen embrittlement when cathodically charged or plated without bake-out; avoid strong reducing acids.

Sustainability4

Producing a kilogram of Custom 455-H1050 takes about 65 MJ of energy and emits 5.2 kg of CO₂ — more than 96% of steel grades. Typical recycled content is 30%.

Embodied Energy (primary production)65 MJ/kg27,945 BTU/lb
Embodied Carbon (primary production)5.2 kg CO₂/kg
Embodied Water120 L/kg14.4 gal/lb
Typical Recycled Content30%

Manufacturability8

Custom 455-H1050's machinability is poor (28/100, worse than 91% of steel grades); weldability fair (45/100); formability poor (28/100).

MachinabilityPoor28/100
Machinability Rating (AISI 1212 = 100 %)33%
WeldabilityFair45/100
Formability (cold)Poor28/100
CastabilityPoor20/100
Brazeability / SolderabilityFair35/100
PolishabilityVery good80/100
Anodizing Responsen/a — steels are not anodized; use passivation or Cd/Al-ceramic coatings for aerospace fasteners

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Custom 455-H1050

Is Custom 455 easy to machine?

Machine in Condition A with rigid setups, positive-rake carbide, heavy coolant and low speeds; aged H900–H1000 material work-hardens strongly and is best ground or turned with reduced feeds.

Can Custom 455 be welded?

GTAW/EBW without filler or with matching wire is practical; re-solution-treat and re-age (or at minimum re-age) after welding to restore joint strength, and avoid weld cracking by keeping heat input low.

Can Custom 455 be formed, bent or molded?

Cold form, bend and cold-head only in Condition A with generous radii; aging at 480–565 °C causes very little distortion so parts can be finished close to final size before hardening.

What surface finishes work on Custom 455?

Passivate per AMS 2700 after machining; avoid electroplating without a post-plate hydrogen bake-out, and expect excellent response to polishing and shot peening for fatigue improvement.

Custom 455 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
C≤ 0.030.02
Mn≤ 0.50.25
Si≤ 0.50.25
P≤ 0.04—
S≤ 0.03—
Cr11 – 12.511.75
Ni7.5 – 9.58.5
Mo≤ 0.50.25
Cuprecipitation strengthener1.5 – 2.52
Tiprecipitation strengthener0.8 – 1.41.1
NbCb+Ta0.1 – 0.50.3
Febalance—

Custom 455-H1050 — frequently asked

What is Custom 455-H1050 used for?

Custom 455-H1050 is typically used for aircraft fasteners, landing gear parts, shafts and structural fittings. In short: corrosion-resistant UHS stainless; aerospace fastener grade; minimal aging distortion.

What is the yield strength of Custom 455-H1050?

Custom 455-H1050 has a typical yield strength of 1,380 MPa (200 ksi) and a tensile strength of 1,450 MPa (210 ksi) — stronger than 96% of steel grades. Strength varies by condition: see the 6 listed tempers.

Is Custom 455-H1050 easy to machine?

Not especially — machinability is rated poor (28/100, worse than 91% of steel grades). Machine in Condition A with rigid setups, positive-rake carbide, heavy coolant and low speeds; aged H900–H1000 material work-hardens strongly and is best ground or turned with reduced feeds.

Can Custom 455-H1050 be welded?

With care — weldability is rated fair (45/100). GTAW/EBW without filler or with matching wire is practical; re-solution-treat and re-age (or at minimum re-age) after welding to restore joint strength, and avoid weld cracking by keeping heat input low.

What surface finishes work on Custom 455-H1050?

Passivate per AMS 2700 after machining; avoid electroplating without a post-plate hydrogen bake-out, and expect excellent response to polishing and shot peening for fatigue improvement.

Can Custom 455-H1050 be formed, bent or molded?

Cold form, bend and cold-head only in Condition A with generous radii; aging at 480–565 °C causes very little distortion so parts can be finished close to final size before hardening.

What is the maximum service temperature of Custom 455-H1050?

Custom 455-H1050 is rated for continuous use to about 450°C (842 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Custom 455-H1000 and Custom 455-A?

H1000 is the default condition — most commonly stocked aged condition — ~225 ksi with the best strength/toughness and stress-corrosion balance. A: pick for machining, cold forming, heading or welding before a single low-temperature aging cycle. Yield strength is 1,450 MPa in H1000 versus 795 MPa in A.

Sources

  1. ASTM A564/A564M — Age-Hardening Stainless Steel Bars and Shapes (Type XM-16) — ASTM International (2019)
  2. Custom 455 Stainless alloy technical datasheet — Carpenter Technology (2021)
  3. AMS 5617 / AMS 5860 — S45500 bar, wire and forgings — SAE International (2018)
  4. ASM Handbook Vol. 1: Properties and Selection — Irons, Steels, and High-Performance Alloys — ASM International (1990)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.