FabDigitFabDigit

Maple HARD-GREEN

Grade

Freshly sawn stock for turning, steam-bending or resawing before drying; strength and stiffness are markedly lower and shrinkage is still to come.

Standard cost $$

Values for the HARD-GREEN condition

Other Maple tempers and conditions

Maple is listed in 3 conditions; see the grade overview at Maple.

Compare all 3 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
HARD-GREENThis page
Hard maple, green (above fibre saturation, ~ 65 % MC)
Freshly sawn stock for turning, steam-bending or resawing before drying; strength and stiffness are markedly lower and shrinkage is still to come.—70——0.32 W/m·K
Soft maple, kiln-dried
Pick when cost and easier machining matter more than wear resistance — painted furniture, mouldings, jig bodies, drawer sides.—85——0.14 W/m·K
HARD-KDDefault
Hard maple, kiln-dried
Default choice for flooring, butcher block, bowling pins, instrument necks and tooling jigs where hardness and dimensional stability matter.—1001.5—0.16 W/m·K

What is Maple HARD-GREEN?

Maple HARD-GREEN is Maple in the HARD-GREEN grade — freshly sawn stock for turning, steam-bending or resawing before drying; strength and stiffness are markedly lower and shrinkage is still to come. Maple HARD-GREEN has a tensile strength of 70 MPa (10.2 ksi), stronger than 67% of natural material grades. Elongation at break is 1.5% and the elastic modulus is 10.7 GPa (1.55 Msi). Maple HARD-GREEN has a density of 0.99 g/cm³ (0.0358 lb/in³), heavier than 79% of natural material grades. HARD-KD is the default condition FabDigit quotes; HARD-GREEN is available on request or by drawing note.

Advantages

  • Polishes to a fine finish — 88/100, better than 94% of natural material grades
  • Conducts heat well — 0.32 W/m·K (0.185 BTU/hr·ft·°F), better than 81% of natural material grades

Limitations

  • Limited service temperature — 60°C (140 °F), worse than 94% of natural material grades
  • Difficult to machine — 55/100, worse than 91% of natural material grades
  • Heavy — 0.99 g/cm³ (0.0358 lb/in³), worse than 79% of natural material grades

Maple HARD-GREEN properties

Typical room-temperature values for Maple HARD-GREEN; 10 are specific to this condition. Other listed values are Maple reference data and may not represent this condition. Bars are the position among natural material grades.

Physical2

Maple HARD-GREEN has a density of 0.99 g/cm³ (0.0358 lb/in³), heavier than 79% of natural material grades.

Density0.99 g/cm³0.04 lb/in³
Porosity55%

Mechanical9

Maple HARD-GREEN has a tensile strength of 70 MPa (10.2 ksi), stronger than 67% of natural material grades. Elongation at break is 1.5% and the elastic modulus is 10.7 GPa (1.55 Msi).

Elastic (Young's) Modulus10.7 GPa1.6 Msi
Shear Modulus1.4 GPa0.2 Msi
Poisson's Ratio0.42
Tensile Strength (Ultimate)70 MPa10.2 ksi
Elongation at Break1.5%
Compressive Strength28 MPa4 ksi
Flexural Strength65 MPa9.4 ksi
Shear Strength13 MPa1.9 ksi
Fracture Toughness (K_IC)0.6 MPa·√m0.55 ksi·√in

Thermal5

Maple HARD-GREEN is rated for continuous service to 60°C (140 °F). It conducts heat at 0.32 W/m·K (0.185 BTU/hr·ft·°F), better than 81% of natural material grades. Thermal expansion is 4 µm/m·K (2.22 µin/in·°F).

Thermal Conductivity0.32 W/m·K0.18 BTU/hr·ft·°F
Specific Heat Capacity1,650 J/kg·K0.39 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)4 µm/m·K2.2 µin/in·°F
Max Service Temperature (continuous)60°C140 °F
Min Service Temperature-60°C-76 °F

Electrical2

Maple HARD-GREEN is an electrical insulator with a dielectric strength of 4 kV/mm (101.6 V/mil) and a resistivity of 1,000 Ω·m.

Electrical Resistivity1,000 Ω·m3.94×10¹⁰ µΩ·in
Dielectric Strength4 kV/mm102 V/mil

Chemical & Environmental1

Corrosion resistance is fair (45/100), better than 53% of natural material grades.

Corrosion ResistanceFair45/100

Sustainability4

Producing a kilogram of Maple HARD-GREEN takes about 10 MJ of energy and emits 0.45 kg of CO₂ — less than 56% of natural material grades. Typical recycled content is 5%.

Embodied Energy (primary production)10 MJ/kg4,299 BTU/lb
Embodied Carbon (primary production)0.45 kg CO₂/kg
Embodied Water650 L/kg77.9 gal/lb
Typical Recycled Content5%

Manufacturability2

Maple HARD-GREEN's machinability is good (55/100, worse than 91% of natural material grades).

MachinabilityGood55/100
PolishabilityExcellent88/100

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Maple HARD-GREEN

Is Maple easy to machine?

Cuts and turns cleanly with carbide tooling, but low feed rates cause scorching — use sharp tools, high SFM with adequate chip clearance and light finishing passes.

Can Maple be welded?

Not weldable; joined by PVA/epoxy/polyurethane adhesives or mechanical fasteners with pre-drilled pilot holes to avoid splitting.

Can Maple be formed, bent or molded?

Steam-bends moderately well (hard maple is only fair, soft maple better); air/kiln-dry to 6–8 % MC and allow for ~9 % tangential shrinkage before machining critical dimensions.

What surface finishes work on Maple?

Dense closed pores blotch with pigment stains — use a washcoat/gel stain or dye; sands to a very fine surface and takes lacquer, oil or waterborne finishes to a high sheen.

Maple chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
cellulosestructural microfibrils42 – 4845
hemicellulosemainly glucuronoxylan (hardwood)25 – 3229
ligninsyringyl/guaiacyl type20 – 2522
extractivessugars, phenolics; low in maple1.5 – 4.53
ashCa/K minerals0.2 – 0.60.4
moisturekiln-dried indoor EMC basis6 – 128

Maple HARD-GREEN — frequently asked

What is Maple HARD-GREEN used for?

Maple HARD-GREEN is typically used for flooring, bowling pins/lanes, musical instruments, cutting boards and furniture. In short: hardest common temperate hardwood; clean-machining closed-grain surface; high shock resistance.

What is the tensile strength of Maple HARD-GREEN?

Maple HARD-GREEN has a typical tensile strength of 70 MPa (10.2 ksi) — stronger than 67% of natural material grades. Strength varies by condition: see the 3 listed tempers.

Is Maple HARD-GREEN easy to machine?

Reasonably — machinability is rated good (55/100, worse than 91% of natural material grades). Cuts and turns cleanly with carbide tooling, but low feed rates cause scorching — use sharp tools, high SFM with adequate chip clearance and light finishing passes.

Can Maple HARD-GREEN be welded?

Not weldable; joined by PVA/epoxy/polyurethane adhesives or mechanical fasteners with pre-drilled pilot holes to avoid splitting.

What surface finishes work on Maple HARD-GREEN?

Dense closed pores blotch with pigment stains — use a washcoat/gel stain or dye; sands to a very fine surface and takes lacquer, oil or waterborne finishes to a high sheen.

Can Maple HARD-GREEN be formed, bent or molded?

Steam-bends moderately well (hard maple is only fair, soft maple better); air/kiln-dry to 6–8 % MC and allow for ~9 % tangential shrinkage before machining critical dimensions.

What is the maximum service temperature of Maple HARD-GREEN?

Maple HARD-GREEN is rated for continuous use to about 60°C (140 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Wood Handbook — Wood as an Engineering Material, FPL-GTR-190, Ch.5 Mechanical Properties — USDA Forest Products Laboratory (2021)
  2. EN 13556 — Round and sawn timber: nomenclature of timbers used in Europe (ACSA/ACRU codes) — CEN (2003)
  3. ASTM D143 — Standard Test Methods for Small Clear Specimens of Timber — ASTM International (2022)
  4. NHLA Rules for the Measurement and Inspection of Hardwood Lumber — National Hardwood Lumber Association (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.