FabDigitFabDigit

Steel P2 vs P4

Steel · grade comparison

Steel P2 and P4 are both steel grades. P2 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 300 MPa (43.5 ksi) for P4, about 10% more. P4 is harder — 122 HB against 110 HB for P2 — which matters for wear surfaces and threads. P2 conducts heat better (40 W/m·K vs 26 W/m·K). On the shop floor, P2 machines more easily (very good vs good), P2 welds better (good vs fair), and P2 forms better (very good vs good).

P2Choose it when strength drives the design, or when the part is machined in volume.

P4Choose it when surface hardness matters.

P2 vs P4: properties

P2P4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
207 GPa30 Msi

Tensile Strength (Ultimate)

510 MPa74 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
300 MPa43.5 ksi

Elongation at Break

27%
25%

Reduction in Area

58%
55%

Compressive Strength

340 MPa49.3 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
—

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

110 HB
122 HB

Hardness, Rockwell B

63 HRB
69 HRB

Hardness, Vickers

115 HV
128 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 330 MPa47.9 ksi

Physical

Density and transition temperatures.

Density

7.85 g/cm³0.28 lb/in³
7.8 g/cm³0.28 lb/in³

Liquidus Temperature

1,500°C2,732 °F
1,490°C2,714 °F

Same in both: Melting Point (Solidus) 1,420°C2,588 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

40 W/m·K23.1 BTU/hr·ft·°F
26 W/m·K15 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

12.4 µm/m·K6.9 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Min Service Temperature

-20°C-4 °F
-30°C-22 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.5 % IACS
2.9 % IACS

Electrical Resistivity

2×10⁻⁷ Ω·m7.87 µΩ·in
6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.6 V

Corrosion Resistance

12 / 100
20 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

60 / 100
45 / 100

Formability (cold)

70 / 100
60 / 100

Castability

35 / 100
30 / 100

Brazeability / Solderability

55 / 100
50 / 100

Polishability

75 / 100
88 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

34 MJ/kg14,617 BTU/lb
32 MJ/kg13,758 BTU/lb

Typical Recycled Content

35%
30%

Same in both: Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

65 kN·m/kg
64 kN·m/kg

Specific Stiffness (E / density)

26.1 MN·m/kg
26.5 MN·m/kg

Modulus of Resilience

266 kJ/m³
217 kJ/m³

Thermal Diffusivity

11.1 mm²/s
7.2 mm²/s

Thermal Shock Resistance Index

8
5

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP2P4

Manufacturing and finishing

CapabilityP2P4
Default condition——
Relative cost$$$ Premium$$$ Premium
Min. machined wall——
Best machined surface——

Both take the same 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

P2 vs P4 — frequently asked

Is P2 stronger than P4?

Yes. P2 has a typical yield strength of 330 MPa (47.9 ksi) against 300 MPa (43.5 ksi) for P4 — about 10% more. Tensile strength is 510 MPa (74 ksi) vs 500 MPa (72.5 ksi).

Which is cheaper, P2 or P4?

Both sit in the same relative cost tier ($$$, premium); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, P2 or P4?

P2. Its machinability rates very good (70/100) against good (60/100) for P4; for welding the order is P2 first (good, 60/100) then P4 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in P2 and P4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.