FabDigitFabDigit

Steel DC06 vs DD11

Steel · grade comparison

Steel DC06 and DD11 are both steel grades. DD11 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 150 MPa (21.8 ksi) for DC06, about 47% more; tensile strength follows at 380 MPa (55.1 ksi) vs 300 MPa (43.5 ksi). In exchange, DC06 is the more ductile: elongation 42% versus 32% for DD11, and DD11 is harder (110 HB vs 88 HB). DD11 runs hotter in service (350°C vs 250°C continuous) and DC06 conducts heat better (58 W/m·K vs 51 W/m·K). On the shop floor, DD11 machines more easily (good vs fair).

DC06Choose it when the part is bent, formed or impact-loaded.

DD11Choose it when strength drives the design, or when the part sees heat.

DC06 vs DD11: properties

DC06DD11

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
220 MPa31.9 ksi

Elongation at Break

42%
32%

Reduction in Area

70%
60%

Compressive Strength

150 MPa21.8 ksi
220 MPa31.9 ksi

Shear Strength

200 MPa29 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
180 MPa26.1 ksi

Fracture Toughness (K_IC)

140 MPa·√m127 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

88 HB
110 HB

Hardness, Rockwell B

42 HRB
63 HRB

Hardness, Vickers

92 HV
115 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,500°C2,732 °F
1,490°C2,714 °F

Liquidus Temperature

1,535°C2,795 °F
1,520°C2,768 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

58 W/m·K33.5 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Latent Heat of Fusion

247 J/g106 BTU/lb
270 J/g116 BTU/lb

Max Service Temperature (continuous)

250°C482 °F
350°C662 °F

Min Service Temperature

-40°C-40 °F
-20°C-4 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F

Electrical

Conductivity and insulation.

Electrical Conductivity

13 % IACS
11 % IACS

Electrical Resistivity

1.4×10⁻⁷ Ω·m5.51 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.6 V
-0.61 V

Same in both: Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
60%

Formability (cold)

99 / 100
75 / 100

Brazeability / Solderability

65 / 100
75 / 100

Polishability

55 / 100
45 / 100

Same in both: Weldability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

26 MJ/kg11,178 BTU/lb
25 MJ/kg10,748 BTU/lb

Embodied Carbon (primary production)

2.2 kg CO₂/kg
2.1 kg CO₂/kg

Embodied Water

35 L/kg4.2 gal/lb
40 L/kg4.8 gal/lb

Typical Recycled Content

20%
25%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

38 kN·m/kg
48 kN·m/kg

Modulus of Resilience

54 kJ/m³
115 kJ/m³

Thermal Diffusivity

15.7 mm²/s
13.8 mm²/s

Thermal Shock Resistance Index

7
8

Same in both: Specific Stiffness (E / density) 26.8 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleDC06DD11

Manufacturing and finishing

CapabilityDC06DD11
Default condition——
Relative cost$ Budget$ Budget
Min. machined wall——
Best machined surface——

Both take the same 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

DC06 vs DD11 — frequently asked

Is DD11 stronger than DC06?

Yes. DD11 has a typical yield strength of 220 MPa (31.9 ksi) against 150 MPa (21.8 ksi) for DC06 — about 47% more. Tensile strength is 380 MPa (55.1 ksi) vs 300 MPa (43.5 ksi).

Which is cheaper, DC06 or DD11?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, DC06 or DD11?

DD11. Its machinability rates good (58/100) against fair (45/100) for DC06.

Ready to make it?

Upload a CAD file and FabDigit prices the part in DC06 and DD11 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.