FabDigitFabDigit

Steel 14G2AF vs A242

Steel · grade comparison

Steel 14G2AF and A242 are both steel grades. 14G2AF is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 370 MPa (53.7 ksi) for A242, about 16% more; tensile strength follows at 580 MPa (84.1 ksi) vs 510 MPa (74 ksi). 14G2AF is harder — 170 HB against 155 HB for A242 — which matters for wear surfaces and threads. 14G2AF runs hotter in service (400°C vs 350°C continuous).

14G2AFChoose it when strength drives the design, or when surface hardness matters.

14G2AF vs A242: properties

14G2AFA242

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

210 GPa30.5 Msi
200 GPa29 Msi

Shear Modulus

81 GPa11.7 Msi
79 GPa11.5 Msi

Tensile Strength (Ultimate)

580 MPa84.1 ksi
510 MPa74 ksi

Yield Strength (0.2% offset)

430 MPa62.4 ksi
370 MPa53.7 ksi

Elongation at Break

22%
24%

Reduction in Area

55%
50%

Compressive Strength

430 MPa62.4 ksi
370 MPa53.7 ksi

Shear Strength

350 MPa50.8 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

265 MPa38.4 ksi
245 MPa35.5 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

170 HB
155 HB

Hardness, Rockwell B

87 HRB
82 HRB

Hardness, Vickers

178 HV
163 HV

Same in both: Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,490°C2,714 °F
1,450°C2,642 °F

Liquidus Temperature

1,520°C2,768 °F
1,510°C2,750 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

12 µm/m·K6.7 µin/in·°F
11.7 µm/m·K6.5 µin/in·°F

Latent Heat of Fusion

270 J/g116 BTU/lb
247 J/g106 BTU/lb

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Min Service Temperature

-70°C-94 °F
-30°C-22 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.5 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.65 V
-0.6 V

Corrosion Resistance

12 / 100
35 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
60%

Weldability

78 / 100
80 / 100

Castability

40 / 100
—

Brazeability / Solderability

55 / 100
40 / 100

Polishability

45 / 100
40 / 100

Same in both: Formability (cold) 65 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

2.1 kg CO₂/kg
1.9 kg CO₂/kg

Typical Recycled Content

25%
30%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Water 40 L/kg4.8 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

74 kN·m/kg
65 kN·m/kg

Specific Stiffness (E / density)

26.8 MN·m/kg
25.5 MN·m/kg

Modulus of Resilience

440 kJ/m³
342 kJ/m³

Thermal Diffusivity

12.5 mm²/s
13 mm²/s

Thermal Shock Resistance Index

11
10

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA24214G2AF

Manufacturing and finishing

Capability14G2AFA242
Default condition——
Relative cost$ Budget$ Budget
Min. machined wall——
Best machined surface——

Both take the same 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

14G2AF vs A242 — frequently asked

Is 14G2AF stronger than A242?

Yes. 14G2AF has a typical yield strength of 430 MPa (62.4 ksi) against 370 MPa (53.7 ksi) for A242 — about 16% more. Tensile strength is 580 MPa (84.1 ksi) vs 510 MPa (74 ksi).

Which is cheaper, 14G2AF or A242?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 14G2AF or A242?

A242. Its machinability rates good (58/100) against fair (52/100) for 14G2AF.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 14G2AF and A242 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.