FabDigitFabDigit

LCP-MF vs LCP Type I

Polymer · grade comparison

LCP-MF and LCP Type I are both polymer grades. LCP Type I is the stronger of the two: tensile strength 135 MPa (19.6 ksi) against 115 MPa (16.7 ksi) for LCP-MF, about 17% more. LCP Type I is the more ductile: elongation 2.5% versus 2% for LCP-MF. LCP Type I is lighter (1.38 g/cm³ vs 1.82 g/cm³ for LCP-MF) and LCP-MF conducts heat better (0.45 W/m·K vs 0.3 W/m·K). On the shop floor, LCP Type I machines more easily (good vs fair).

LCP Type IChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

LCP-MF vs LCP Type I: properties

LCP-MFLCP Type I

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

115 MPa16.7 ksi
135 MPa19.6 ksi

Elongation at Break

2%
2.5%

Compressive Strength

130 MPa18.9 ksi
65 MPa9.4 ksi

Flexural Strength

150 MPa21.8 ksi
145 MPa21 ksi

Flexural Modulus

11.5 GPa1.7 Msi
10 GPa1.5 Msi

Shear Strength

70 MPa10.2 ksi
55 MPa8 ksi

Fracture Toughness (K_IC)

2.5 MPa·√m2.3 ksi·√in
—

Izod Impact, Notched

55 J/m1 ft·lbf/in
180 J/m3.4 ft·lbf/in

Hardness, Rockwell M

85 HRM
75 HRM

Shear Modulus

—
1.2 GPa0.17 Msi

Compressive Modulus

—
7 GPa1 Msi

Hardness, Shore D

—
88 Shore D

Same in both: Elastic (Young's) Modulus 11 GPa1.6 Msi · Poisson's Ratio 0.38

Physical

Density and transition temperatures.

Density

1.82 g/cm³0.07 lb/in³
1.38 g/cm³0.05 lb/in³

Melting Temperature (Tm)

320°C608 °F
355°C671 °F

Glass Transition (Tg)

120°C248 °F
145°C293 °F

Water Absorption (24 h)

0.03%
0.02%

Same in both: Water Absorption (Saturation) 0.1%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.45 W/m·K0.26 BTU/hr·ft·°F
0.3 W/m·K0.17 BTU/hr·ft·°F

Specific Heat Capacity

1,050 J/kg·K0.25 BTU/lb·°F
1,150 J/kg·K0.27 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

22 µm/m·K12.2 µin/in·°F
8 µm/m·K4.4 µin/in·°F

Min Service Temperature

-50°C-58 °F
-100°C-148 °F

Heat Deflection Temp. @ 0.45 MPa

265°C509 °F
275°C527 °F

Heat Deflection Temp. @ 1.8 MPa

235°C455 °F
240°C464 °F

Max Service Temperature (short-term)

280°C536 °F
300°C572 °F

Same in both: Max Service Temperature (continuous) 220°C428 °F · Limiting Oxygen Index 40%

Electrical

Conductivity and insulation.

Dielectric Strength

32 kV/mm813 V/mil
35 kV/mm889 V/mil

Dielectric Constant (1 MHz)

4.2
3.3

Dissipation Factor (1 MHz)

0.006
0.004

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 92 / 100 · UV / Weathering Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
62 / 100

Weldability

25 / 100
20 / 100

Formability (cold)

15 / 100
20 / 100

Polishability

50 / 100
45 / 100

Mold Shrinkage

0.35%
0.1%

Melt Flow Rate

35 g/10 min
—

Processing Melt Temperature (typ.)

340°C644 °F
385°C725 °F

Mold Temperature (typ.)

110°C230 °F
120°C248 °F

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

175 MJ/kg75,237 BTU/lb
250 MJ/kg107,481 BTU/lb

Embodied Carbon (primary production)

8.5 kg CO₂/kg
9 kg CO₂/kg

Embodied Water

260 L/kg31.2 gal/lb
300 L/kg35.9 gal/lb

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

63 kN·m/kg
98 kN·m/kg

Specific Stiffness (E / density)

6 MN·m/kg
8 MN·m/kg

Same in both: Thermal Diffusivity 0.2 mm²/s · Thermal Shock Resistance Index 0

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityLCP-MFLCP Type I
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

LCP-MF vs LCP Type I — frequently asked

Is LCP Type I stronger than LCP-MF?

Yes. LCP Type I has a typical tensile strength of 135 MPa (19.6 ksi) against 115 MPa (16.7 ksi) for LCP-MF — about 17% more.

Which is cheaper, LCP-MF or LCP Type I?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, LCP-MF or LCP Type I?

LCP Type I. Its machinability rates good (62/100) against fair (45/100) for LCP-MF; for welding the order is LCP-MF first (poor, 25/100) then LCP Type I (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP-MF and LCP Type I side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.