FabDigitFabDigit

Gorilla Glass vs JGS1

Glass · grade comparison

Gorilla Glass and JGS1 are both glass grades. Gorilla Glass is the stronger of the two: tensile strength 350 MPa (50.8 ksi) against 50 MPa (7.25 ksi) for JGS1, about 7.0 times as much. JGS1 is harder — 750 HV against 620 HV for Gorilla Glass — which matters for wear surfaces and threads. JGS1 is lighter (2.2 g/cm³ vs 2.42 g/cm³ for Gorilla Glass) and JGS1 runs hotter in service (1,050°C vs 200°C continuous). On the shop floor, Gorilla Glass sits in a lower cost tier (standard, $$) than JGS1 (high, $$$$).

Gorilla GlassChoose it when strength drives the design, or when cost is the deciding factor.

JGS1Choose it when surface hardness matters, or when weight is the constraint.

Gorilla Glass vs JGS1: properties

Gorilla GlassJGS1

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Shear Modulus

29.5 GPa4.3 Msi
31 GPa4.5 Msi

Bulk Modulus

42 GPa6.1 Msi
37 GPa5.4 Msi

Poisson's Ratio

0.21
0.17

Tensile Strength (Ultimate)

350 MPa50.8 ksi
50 MPa7.3 ksi

Compressive Strength

1,000 MPa145 ksi
1,100 MPa160 ksi

Flexural Strength

800 MPa116 ksi
67 MPa9.7 ksi

Hardness, Vickers

620 HV
750 HV

Hardness, Knoop

590 HK
600 HK

Hardness, Mohs

6.5
6

Shear Strength

—
70 MPa10.2 ksi

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Elongation at Break 0% · Fracture Toughness (K_IC) 0.75 MPa·√m0.68 ksi·√in

Physical

Density and transition temperatures.

Density

2.42 g/cm³0.09 lb/in³
2.2 g/cm³0.08 lb/in³

Refractive Index

1.5
1.459

Light Transmission

92%
93%

Melting Point (Solidus)

—
1,713°C3,115 °F

Same in both: Porosity 0%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

1 W/m·K0.58 BTU/hr·ft·°F
1.4 W/m·K0.8 BTU/hr·ft·°F

Specific Heat Capacity

820 J/kg·K0.2 BTU/lb·°F
740 J/kg·K0.18 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

7.9 µm/m·K4.4 µin/in·°F
0.55 µm/m·K0.31 µin/in·°F

Max Service Temperature (continuous)

200°C392 °F
1,050°C1,922 °F

Min Service Temperature

-100°C-148 °F
-200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1×10¹² Ω·m3.94×10¹⁹ µΩ·in
1×10¹⁶ Ω·m3.94×10²³ µΩ·in

Dielectric Strength

15 kV/mm381 V/mil
30 kV/mm762 V/mil

Dielectric Constant (1 MHz)

7.2
3.8

Dissipation Factor (1 MHz)

0.011
1×10⁻⁴

Volume Resistivity

1×10¹⁴ Ω·cm
1×10¹⁸ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

90 / 100
95 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
12 / 100

Polishability

95 / 100
98 / 100

Sintering / Firing Temperature

—
1,800°C3,272 °F

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

35 MJ/kg15,047 BTU/lb
55 MJ/kg23,646 BTU/lb

Embodied Carbon (primary production)

2.6 kg CO₂/kg
4.5 kg CO₂/kg

Embodied Water

25 L/kg3 gal/lb
40 L/kg4.8 gal/lb

Typical Recycled Content

3%
0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

145 kN·m/kg
23 kN·m/kg

Specific Stiffness (E / density)

29.8 MN·m/kg
32.7 MN·m/kg

Thermal Diffusivity

0.5 mm²/s
0.8 mm²/s

Thermal Shock Resistance Index

1
2

Strength versus weight

Yield strength against density for every glass grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005002.533.5Density (g/cm³)Yield strength (MPa) — log scaleGorilla Glass

Manufacturing and finishing

CapabilityGorilla GlassJGS1
Default conditionChem Strengthened—
Relative cost$$ Standard$$$$ High
Min. machined wall——
Best machined surface——

Gorilla Glass vs JGS1 — frequently asked

Is Gorilla Glass stronger than JGS1?

Yes. Gorilla Glass has a typical tensile strength of 350 MPa (50.8 ksi) against 50 MPa (7.25 ksi) for JGS1 — about 7.0 times as much.

Which is cheaper, Gorilla Glass or JGS1?

Gorilla Glass is the lower-cost material: it sits in the standard tier ($$) while JGS1 is high ($$$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, Gorilla Glass or JGS1?

JGS1, by a small margin. Both rate not recommended for machinability — 12/100 against 5/100 for Gorilla Glass.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Gorilla Glass and JGS1 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.