FabDigitFabDigit

3501-6 vs T800H

Composite · grade comparison

3501-6 and T800H are both composite grades. T800H is the stronger of the two: tensile strength 5,490 MPa (796 ksi) against 2,100 MPa (305 ksi) for 3501-6, about 161% more. T800H is the more ductile: elongation 1.9% versus 1.5% for 3501-6. 3501-6 is lighter (1.58 g/cm³ vs 1.81 g/cm³ for T800H) and T800H is stiffer (294 GPa vs 142 GPa). On the shop floor, 3501-6 machines more easily (fair vs poor).

3501-6Choose it when weight is the constraint, or when the part is machined in volume.

T800HChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

3501-6 vs T800H: properties

3501-6T800H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

142 GPa20.6 Msi
294 GPa42.6 Msi

Shear Modulus

7.1 GPa1 Msi
—

Poisson's Ratio

0.3
—

Tensile Strength (Ultimate)

2,100 MPa305 ksi
5,490 MPa796 ksi

Elongation at Break

1.5%
1.9%

Compressive Strength

1,480 MPa215 ksi
2,400 MPa348 ksi

Compressive Modulus

130 GPa18.9 Msi
—

Flexural Strength

1,750 MPa254 ksi
—

Flexural Modulus

130 GPa18.9 Msi
—

Shear Strength

95 MPa13.8 ksi
—

Physical

Density and transition temperatures.

Density

1.58 g/cm³0.06 lb/in³
1.81 g/cm³0.07 lb/in³

Glass Transition (Tg)

200°C392 °F
—

Water Absorption (24 h)

0.1%
—

Water Absorption (Saturation)

1.4%
—

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

4 W/m·K2.3 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Specific Heat Capacity

950 J/kg·K0.23 BTU/lb·°F
750 J/kg·K0.18 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

-0.4 µm/m·K-0.22 µin/in·°F
-0.56 µm/m·K-0.31 µin/in·°F

Max Service Temperature (continuous)

121°C250 °F
400°C752 °F

Min Service Temperature

-55°C-67 °F
-269°C-452 °F

Limiting Oxygen Index

35%
—

Max Service Temperature (short-term)

177°C351 °F
500°C932 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.6×10⁻⁵ Ω·m630 µΩ·in
1.4×10⁻⁵ Ω·m551 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

88 / 100
92 / 100

UV / Weathering Resistance

25 / 100
85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
18 / 100

Polishability

40 / 100
—

Mold Temperature (typ.)

177°C351 °F
—

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

300 MJ/kg128,977 BTU/lb
500 MJ/kg214,962 BTU/lb

Embodied Carbon (primary production)

24 kg CO₂/kg
34 kg CO₂/kg

Embodied Water

450 L/kg53.9 gal/lb
600 L/kg71.9 gal/lb

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

1,329 kN·m/kg
3,033 kN·m/kg

Specific Stiffness (E / density)

89.9 MN·m/kg
162.4 MN·m/kg

Thermal Diffusivity

2.7 mm²/s
25.8 mm²/s

Thermal Shock Resistance Index

-148
-1,167

Strength versus weight

Yield strength against density for every composite grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1101001,000510Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

Capability3501-6T800H
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

3501-6 vs T800H — frequently asked

Is T800H stronger than 3501-6?

Yes. T800H has a typical tensile strength of 5,490 MPa (796 ksi) against 2,100 MPa (305 ksi) for 3501-6 — about 161% more.

Which is cheaper, 3501-6 or T800H?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 3501-6 or T800H?

3501-6. Its machinability rates fair (35/100) against poor (18/100) for T800H.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3501-6 and T800H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.