FabDigitFabDigit

3501-6 vs T700S

Composite · grade comparison

3501-6 and T700S are both composite grades. T700S is the stronger of the two: tensile strength 4,900 MPa (711 ksi) against 2,100 MPa (305 ksi) for 3501-6, about 133% more. T700S is the more ductile: elongation 2.1% versus 1.5% for 3501-6. 3501-6 is lighter (1.58 g/cm³ vs 1.8 g/cm³ for T700S) and T700S is stiffer (230 GPa vs 142 GPa). On the shop floor, 3501-6 machines more easily (fair vs poor).

3501-6Choose it when weight is the constraint, or when the part is machined in volume.

T700SChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

3501-6 vs T700S: properties

3501-6T700S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

142 GPa20.6 Msi
230 GPa33.4 Msi

Shear Modulus

7.1 GPa1 Msi
—

Poisson's Ratio

0.3
0.27

Tensile Strength (Ultimate)

2,100 MPa305 ksi
4,900 MPa711 ksi

Elongation at Break

1.5%
2.1%

Compressive Strength

1,480 MPa215 ksi
1,470 MPa213 ksi

Compressive Modulus

130 GPa18.9 Msi
—

Flexural Strength

1,750 MPa254 ksi
1,620 MPa235 ksi

Flexural Modulus

130 GPa18.9 Msi
120 GPa17.4 Msi

Shear Strength

95 MPa13.8 ksi
98 MPa14.2 ksi

Physical

Density and transition temperatures.

Density

1.58 g/cm³0.06 lb/in³
1.8 g/cm³0.07 lb/in³

Glass Transition (Tg)

200°C392 °F
—

Water Absorption (24 h)

0.1%
—

Water Absorption (Saturation)

1.4%
—

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

4 W/m·K2.3 BTU/hr·ft·°F
9.4 W/m·K5.4 BTU/hr·ft·°F

Specific Heat Capacity

950 J/kg·K0.23 BTU/lb·°F
750 J/kg·K0.18 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

-0.4 µm/m·K-0.22 µin/in·°F
-0.38 µm/m·K-0.21 µin/in·°F

Max Service Temperature (continuous)

121°C250 °F
350°C662 °F

Min Service Temperature

-55°C-67 °F
-269°C-452 °F

Limiting Oxygen Index

35%
—

Max Service Temperature (short-term)

177°C351 °F
500°C932 °F

Electrical

Conductivity and insulation.

Volume Resistivity

—
0 Ω·cm

Same in both: Electrical Resistivity 1.6×10⁻⁵ Ω·m630 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

88 / 100
90 / 100

UV / Weathering Resistance

25 / 100
60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
25 / 100

Polishability

40 / 100
—

Mold Temperature (typ.)

177°C351 °F
—

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

300 MJ/kg128,977 BTU/lb
400 MJ/kg171,969 BTU/lb

Embodied Carbon (primary production)

24 kg CO₂/kg
28 kg CO₂/kg

Embodied Water

450 L/kg53.9 gal/lb
—

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

1,329 kN·m/kg
2,722 kN·m/kg

Specific Stiffness (E / density)

89.9 MN·m/kg
127.8 MN·m/kg

Thermal Diffusivity

2.7 mm²/s
7 mm²/s

Thermal Shock Resistance Index

-148
-527

Strength versus weight

Yield strength against density for every composite grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1101001,000510Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

Capability3501-6T700S
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

3501-6 vs T700S — frequently asked

Is T700S stronger than 3501-6?

Yes. T700S has a typical tensile strength of 4,900 MPa (711 ksi) against 2,100 MPa (305 ksi) for 3501-6 — about 133% more.

Which is cheaper, 3501-6 or T700S?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 3501-6 or T700S?

3501-6. Its machinability rates fair (35/100) against poor (25/100) for T700S.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3501-6 and T700S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.