FabDigitFabDigit

Aluminum 2017A vs 2A90

Aluminum · grade comparison

Aluminum 2017A and 2A90 are both aluminum grades. 2A90 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 260 MPa (37.7 ksi) for 2017A, about 15% more. In exchange, 2017A is the more ductile: elongation 14% versus 10% for 2A90, and 2A90 is harder (120 HB vs 110 HB). 2A90 runs hotter in service (200°C vs 120°C continuous). On the shop floor, 2017A machines more easily (very good vs good) and 2017A sits in a lower cost tier (premium, $$$) than 2A90 (high, $$$$).

2017AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

2A90Choose it when strength drives the design, or when the part sees heat.

2017A vs 2A90: properties

2017A2A90

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

72.5 GPa10.5 Msi
74 GPa10.7 Msi

Shear Modulus

27 GPa3.9 Msi
28 GPa4.1 Msi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
300 MPa43.5 ksi

Elongation at Break

14%
10%

Compressive Strength

260 MPa37.7 ksi
310 MPa45 ksi

Shear Strength

260 MPa37.7 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
115 MPa16.7 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
25 MPa·√m22.8 ksi·√in

Hardness, Brinell

110 HB
120 HB

Hardness, Rockwell B

62 HRB
71 HRB

Hardness, Vickers

118 HV
128 HV

Reduction in Area

—
20%

Same in both: Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Tensile Strength (Ultimate) 410 MPa59.5 ksi

Physical

Density and transition temperatures.

Density

2.79 g/cm³0.1 lb/in³
2.8 g/cm³0.1 lb/in³

Melting Point (Solidus)

512°C954 °F
510°C950 °F

Liquidus Temperature

641°C1,186 °F
640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

134 W/m·K77.4 BTU/hr·ft·°F
140 W/m·K80.9 BTU/hr·ft·°F

Specific Heat Capacity

873 J/kg·K0.21 BTU/lb·°F
875 J/kg·K0.21 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

23 µm/m·K12.8 µin/in·°F
21.8 µm/m·K12.1 µin/in·°F

Max Service Temperature (continuous)

120°C248 °F
200°C392 °F

Same in both: Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

34 % IACS
37 % IACS

Electrical Resistivity

5.07×10⁻⁸ Ω·m2 µΩ·in
4.7×10⁻⁸ Ω·m1.85 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.69 V
-0.7 V

Corrosion Resistance

35 / 100
33 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
80%

Weldability

20 / 100
22 / 100

Formability (cold)

45 / 100
25 / 100

Castability

25 / 100
—

Same in both: Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

1,100 L/kg132 gal/lb
1,150 L/kg138 gal/lb

Typical Recycled Content

25%
15%

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

147 kN·m/kg
146 kN·m/kg

Specific Stiffness (E / density)

26 MN·m/kg
26.4 MN·m/kg

Modulus of Resilience

466 kJ/m³
608 kJ/m³

Thermal Diffusivity

55 mm²/s
57.1 mm²/s

Thermal Shock Resistance Index

33
36

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2017A2A90

Manufacturing and finishing

Capability2017A2A90
CNC machiningYes—
Sheet metalYes—
Default condition——
Relative cost$$$ Premium$$$$ High
Min. machined wall0.8 mm—
Best machined surfaceRa 0.8 µm—
Anodizing Type IIYes—
CerakoteYes—
Chem Film (Alodine)Yes—
DLCYes—
E-CoatingYes—
ElectropolishingYes—
Hard Anodize Type III w/ PTFEYes—
Hard Anodizing Type IIIYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—
Powder CoatingYes—

They share 4 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Silver Plating.

2017A vs 2A90 — frequently asked

Is 2A90 stronger than 2017A?

Yes. 2A90 has a typical yield strength of 300 MPa (43.5 ksi) against 260 MPa (37.7 ksi) for 2017A — about 15% more. Tensile strength is 410 MPa (59.5 ksi) vs 410 MPa (59.5 ksi).

Which is cheaper, 2017A or 2A90?

2017A is the lower-cost material: it sits in the premium tier ($$$) while 2A90 is high ($$$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 2017A or 2A90?

2017A. Its machinability rates very good (75/100) against good (65/100) for 2A90.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2017A and 2A90 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.