FabDigitFabDigit

Cobalt-Chrome Alloy Phynox-CW (Cold worked)

Supply condition

UNS R30008

Standard as-supplied strip/wire condition for coiling and stamping springs that will be aged afterwards.

High cost $$$$

Values for the CW condition

Other Phynox tempers and conditions

Phynox is listed in 4 conditions; see the grade overview at Phynox.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Solution annealed
Pick for deep drawing, deep bending or machining before final cold work/ageing.4509505526 HRC—
1/2 Hard
Compromise temper for parts needing some bending or forming yet moderate spring strength.1,2501,4501045 HRC1.8 % IACS
CWThis page
Cold worked
Standard as-supplied strip/wire condition for coiling and stamping springs that will be aged afterwards.1,6001,800552 HRC—
CW+ADefault
Cold worked and age hardened
Final high-strength spring/stent condition: maximum strength, fatigue life and relaxation resistance after forming.1,8502,050357 HRC—

What is Phynox-CW?

Phynox-CW is Phynox supplied in the CW condition — standard as-supplied strip/wire condition for coiling and stamping springs that will be aged afterwards. Phynox-CW has a yield strength of 1,600 MPa (232 ksi) and a tensile strength of 1,800 MPa (261 ksi) — stronger than 92% of cobalt-chrome alloy grades. Elongation at break is 5% and the elastic modulus is 215 GPa (31.2 Msi). Phynox-CW has a density of 8.3 g/cm³ (0.3 lb/in³), lighter than 80% of cobalt-chrome alloy grades. It melts at 1,440°C (2,624 °F). CW+A is the default condition FabDigit quotes; CW is available on request or by drawing note.

Advantages

  • High strength — 1,600 MPa (232 ksi), better than 92% of cobalt-chrome alloy grades
  • Low embodied carbon — 9.5 kg CO₂/kg, better than 87% of cobalt-chrome alloy grades
  • Forms and bends easily — 22/100, better than 82% of cobalt-chrome alloy grades

Limitations

  • Limited service temperature — 350°C (662 °F), worse than 100% of cobalt-chrome alloy grades

Phynox-CW properties

Typical room-temperature values for Phynox-CW; 12 are specific to this condition. Other listed values are Phynox reference data and may not represent this condition. Bars are the position among cobalt-chrome alloy grades.

Physical3

Phynox-CW has a density of 8.3 g/cm³ (0.3 lb/in³), lighter than 80% of cobalt-chrome alloy grades. It melts at 1,440°C (2,624 °F).

Density8.3 g/cm³0.3 lb/in³
Melting Point (Solidus)1,440°C2,624 °F
Liquidus Temperature1,495°C2,723 °F

Mechanical12

Phynox-CW has a yield strength of 1,600 MPa (232 ksi) and a tensile strength of 1,800 MPa (261 ksi) — stronger than 92% of cobalt-chrome alloy grades. Elongation at break is 5% and the elastic modulus is 215 GPa (31.2 Msi).

Elastic (Young's) Modulus215 GPa31.2 Msi
Shear Modulus85 GPa12.3 Msi
Bulk Modulus175 GPa25.4 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)1,800 MPa261 ksi
Yield Strength (0.2% offset)1,600 MPa232 ksi
Elongation at Break5%
Compressive Strength1,900 MPa276 ksi
Shear Strength1,080 MPa157 ksi
Fatigue Strength (Endurance Limit)700 MPa102 ksi
Hardness, Rockwell C52 HRC
Hardness, Vickers550 HV

Thermal5

Phynox-CW is rated for continuous service to 350°C (662 °F). It conducts heat at 12.6 W/m·K (7.28 BTU/hr·ft·°F), worse than 71% of cobalt-chrome alloy grades. Thermal expansion is 13.5 µm/m·K (7.5 µin/in·°F).

Thermal Conductivity12.6 W/m·K7.3 BTU/hr·ft·°F
Specific Heat Capacity430 J/kg·K0.1 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)13.5 µm/m·K7.5 µin/in·°F
Max Service Temperature (continuous)350°C662 °F
Min Service Temperature-196°C-321 °F

Electrical3

Phynox-CW conducts electricity at 1.7 % IACS, worse than 92% of cobalt-chrome alloy grades.

Electrical Conductivity1.7 % IACS
Electrical Resistivity1.02×10⁻⁶ Ω·m40.2 µΩ·in
Magnetic Responseweakly magnetic

Chemical & Environmental3

Corrosion resistance is excellent (85/100), better than 79% of cobalt-chrome alloy grades.

Galvanic Potential (seawater, vs SCE)-0.2 V
Corrosion ResistanceExcellent85/100
Chemical Resistance SummaryPassive in body fluids, seawater and most oxidising media; good pitting/crevice resistance thanks to 20 Cr + 7 Mo; attacked by hot concentrated HCl and strongly reducing acids; sulphide/chloride stress-corrosion resistance far better than austenitic stainless steels.

Sustainability3

Producing a kilogram of Phynox-CW takes about 130 MJ of energy and emits 9.5 kg of CO₂ — less than 89% of cobalt-chrome alloy grades. Typical recycled content is 20%.

Embodied Energy (primary production)130 MJ/kg55,890 BTU/lb
Embodied Carbon (primary production)9.5 kg CO₂/kg
Typical Recycled Content20%

Manufacturability7

Phynox-CW's machinability is not recommended (12/100, better than 61% of cobalt-chrome alloy grades); weldability fair (40/100); formability poor (22/100).

MachinabilityNot recommended12/100
Machinability Rating (AISI 1212 = 100 %)8%
WeldabilityFair40/100
Formability (cold)Poor22/100
Brazeability / SolderabilityFair45/100
PolishabilityExcellent85/100
Anodizing Responsen/a — cobalt alloy; use electropolishing or passivation instead of anodising

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Phynox-CW

Is Phynox easy to machine?

Very difficult and highly work-hardening — machine in the annealed condition with rigid setups, positive-rake carbide or ceramic tooling, low speed, heavy feed and flood coolant; grinding/EDM preferred for aged parts.

Can Phynox be welded?

Resistance, micro-TIG and laser welding are used for medical assemblies; filler-free autogenous joints are best, and any weld locally destroys the cold-work/ageing strengthening, so re-age or design joints out of high-stress zones.

Can Phynox be formed, bent or molded?

Coil, stamp or bend in the annealed or spring temper, then age 500–550 °C for 4–5 h to reach full strength; allow for springback and use generous bend radii on cold-worked stock.

What surface finishes work on Phynox?

Electropolishing and passivation give the bright, low-inclusion medical surface; mechanical polishing to mirror finish is easy, PVD or gold plating is possible, anodising is not applicable.

Phynox chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Co39 – 4140
Cr19 – 2120
Ni14 – 1816
Mo6.5 – 7.57
Mn1.5 – 2.52
C≤ 0.150.1
Beberyllium-free grade (unlike F1058 Grade 1 / Elgiloy)≤ 00
Si≤ 1.20.3
P≤ 0.02—
S≤ 0.02—
Febalance, typically ≈15 %balance—

Phynox-CW — frequently asked

What is Phynox-CW used for?

Phynox-CW is typically used for coronary stents, surgical springs and guidewires. In short: medical-grade cobalt spring alloy; biocompatible fatigue performance; fine wire and strip.

What is the yield strength of Phynox-CW?

Phynox-CW has a typical yield strength of 1,600 MPa (232 ksi) and a tensile strength of 1,800 MPa (261 ksi) — stronger than 92% of cobalt-chrome alloy grades. Strength varies by condition: see the 4 listed tempers.

Is Phynox-CW easy to machine?

Not especially — machinability is rated not recommended (12/100, better than 61% of cobalt-chrome alloy grades). Very difficult and highly work-hardening — machine in the annealed condition with rigid setups, positive-rake carbide or ceramic tooling, low speed, heavy feed and flood coolant; grinding/EDM preferred for aged parts.

Can Phynox-CW be welded?

With care — weldability is rated fair (40/100). Resistance, micro-TIG and laser welding are used for medical assemblies; filler-free autogenous joints are best, and any weld locally destroys the cold-work/ageing strengthening, so re-age or design joints out of high-stress zones.

What surface finishes work on Phynox-CW?

Electropolishing and passivation give the bright, low-inclusion medical surface; mechanical polishing to mirror finish is easy, PVD or gold plating is possible, anodising is not applicable.

Can Phynox-CW be formed, bent or molded?

Coil, stamp or bend in the annealed or spring temper, then age 500–550 °C for 4–5 h to reach full strength; allow for springback and use generous bend radii on cold-worked stock.

What is the maximum service temperature of Phynox-CW?

Phynox-CW is rated for continuous use to about 350°C (662 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Phynox CW+A and Phynox-A?

CW+A is the default condition — final high-strength spring/stent condition: maximum strength, fatigue life and relaxation resistance after forming. A: pick for deep drawing, deep bending or machining before final cold work/ageing. Yield strength is 1,850 MPa in CW+A versus 450 MPa in A.

Sources

  1. ASTM F1058 — Wrought 40Co-20Cr-16Fe-15Ni-7Mo Alloy Wire and Strip for Surgical Implants — ASTM International (2016)
  2. Phynox cobalt alloy technical data — Aubert & Duval (2021)
  3. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials — ASM International (1990)
  4. ASM Handbook Vol. 13B — Corrosion: Materials — ASM International (2005)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.