FabDigitFabDigit

XXX

Grade

ASTM D709 Grade XX

XXX = high-humidity electrical paper-phenolic

Pick for radio-frequency / high-humidity insulation where lower loss and lower moisture pickup matter more than strength.

Standard cost $$

Values for the XXX condition

Other XX grades and fills

XX is listed in 7 conditions; see the grade overview at XX.

Compare all 7 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Thin cold-punch paper-phenolic
Thin-sheet grade that cold-punches cleanly at 0.8–1.6 mm; historic single-sided PCB substrate.—85295 HRM
Cold-punching mechanical paper-phenolic
Use where room-temperature punching of gaskets/washers is the priority and electrical values are secondary.—90295 HRM
Flame-retardant paper-phenolic, UL 94 V-0
Specify when a V-0 rating is mandatory (consumer electronics, appliance insulation) in a paper-phenolic price class.—951.8100 HRM
Hot-punching paper-phenolic
Choose when thin blanks must be punched at 80–130 °C without cracking, while keeping near-XX insulation values.—1051.7100 HRM
High-electrical punching grade paper-phenolic
Best combination of low dielectric loss and clean punching; classic terminal-board and coil-form material.—1051.6100 HRM
XXXThis page
High-humidity electrical paper-phenolic
Pick for radio-frequency / high-humidity insulation where lower loss and lower moisture pickup matter more than strength.—1101.4105 HRM
XXDefault
General-purpose mechanical/electrical paper-phenolic sheet
Default machining grade: best balance of strength, electrical properties and cost for milled or drilled insulation parts.—1201.5105 HRM

What is XXX?

XXX is XX in the XXX grade — pick for radio-frequency / high-humidity insulation where lower loss and lower moisture pickup matter more than strength. XXX has a tensile strength of 110 MPa (16 ksi), weaker than 64% of composite grades. Elongation at break is 1.4% and the elastic modulus is 8 GPa (1.16 Msi). XXX has a density of 1.35 g/cm³ (0.0488 lb/in³), lighter than 75% of composite grades. Its glass-transition temperature is 145°C (293 °F). XX is the default condition FabDigit quotes; XXX is available on request or by drawing note.

Advantages

  • Easy to machine — 80/100, better than 85% of composite grades
  • Low embodied carbon — 4.5 kg CO₂/kg, better than 79% of composite grades
  • Lightweight — 1.35 g/cm³ (0.0488 lb/in³), better than 75% of composite grades

Limitations

  • Low fracture toughness — 1.8 MPa·√m (1.64 ksi·√in), worse than 90% of composite grades
  • Degrades in UV without stabilisers — 25/100, worse than 86% of composite grades
  • Poor heat conductor — 0.25 W/m·K (0.144 BTU/hr·ft·°F), worse than 76% of composite grades
  • Needs corrosion protection — 62/100, worse than 75% of composite grades

XXX properties

Typical room-temperature values for XXX; 21 are specific to this condition. Other listed values are XX reference data and may not represent this condition. Bars are the position among composite grades.

Physical4

XXX has a density of 1.35 g/cm³ (0.0488 lb/in³), lighter than 75% of composite grades. Its glass-transition temperature is 145°C (293 °F).

Density1.35 g/cm³0.05 lb/in³
Glass Transition (Tg)145°C293 °F
Water Absorption (24 h)0.8%
Water Absorption (Saturation)4.5%

Mechanical12

XXX has a tensile strength of 110 MPa (16 ksi), weaker than 64% of composite grades. Elongation at break is 1.4% and the elastic modulus is 8 GPa (1.16 Msi).

Elastic (Young's) Modulus8 GPa1.2 Msi
Poisson's Ratio0.25
Tensile Strength (Ultimate)110 MPa16 ksi
Elongation at Break1.4%
Compressive Strength250 MPa36.3 ksi
Compressive Modulus7 GPa1 Msi
Flexural Strength120 MPa17.4 ksi
Flexural Modulus7.5 GPa1.1 Msi
Shear Strength90 MPa13.1 ksi
Fracture Toughness (K_IC)1.8 MPa·√m1.6 ksi·√in
Izod Impact, Notched30 J/m0.56 ft·lbf/in
Hardness, Rockwell M105 HRM

Thermal8

XXX is rated for continuous service to 125°C (257 °F). It conducts heat at 0.25 W/m·K (0.144 BTU/hr·ft·°F), worse than 76% of composite grades. Thermal expansion is 25 µm/m·K (13.9 µin/in·°F).

Thermal Conductivity0.25 W/m·K0.14 BTU/hr·ft·°F
Specific Heat Capacity1,400 J/kg·K0.33 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)25 µm/m·K13.9 µin/in·°F
Max Service Temperature (continuous)125°C257 °F
Min Service Temperature-50°C-58 °F
Flammability (UL 94)HB
Limiting Oxygen Index28%
Max Service Temperature (short-term)150°C302 °F

Electrical7

XXX is an electrical insulator with a dielectric strength of 16 kV/mm (406.4 V/mil) and a resistivity of 1×10¹¹ Ω·m.

Electrical Resistivity1×10¹¹ Ω·m3.94×10¹⁸ µΩ·in
Dielectric Strength16 kV/mm406 V/mil
Dielectric Constant (1 MHz)4.5
Dissipation Factor (1 MHz)0.032
Volume Resistivity1×10¹³ Ω·cm
Surface Resistivity1×10¹¹ Ω
Comparative Tracking Index (CTI)125 V

Chemical & Environmental3

Corrosion resistance is good (62/100), worse than 75% of composite grades. UV resistance is poor.

Corrosion ResistanceGood62/100
UV / Weathering ResistancePoor25/100
Chemical Resistance SummaryGood against oils, greases, transformer fluid, aliphatic solvents and weak acids; attacked by strong alkalis, hot oxidizing acids and steam; hygroscopic paper core swells and loses insulation resistance in prolonged humidity.

Sustainability3

Producing a kilogram of XXX takes about 80 MJ of energy and emits 4.5 kg of CO₂ — less than 84% of composite grades. Typical recycled content is 0%.

Embodied Energy (primary production)80 MJ/kg34,394 BTU/lb
Embodied Carbon (primary production)4.5 kg CO₂/kg
Typical Recycled Content0%

Manufacturability2

XXX's machinability is very good (80/100, better than 85% of composite grades).

MachinabilityVery good80/100
PolishabilityPoor30/100

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with XXX

Is XX easy to machine?

Cuts, drills and taps easily with carbide tooling and high rake; dust is abrasive and irritating, so use vacuum extraction and back-up plates to avoid exit-side delamination.

Can XX be welded?

Not weldable — thermoset; join by bolting, riveting or epoxy/phenolic adhesive bonding after abrasion and solvent wipe.

Can XX be formed, bent or molded?

Supplied fully cured and cannot be post-formed; blanking is done by punching (warm the sheet to 80–130 °C for XX/XXP, room temperature only for XP/XPC/thin stock).

What surface finishes work on XX?

Sanded or scraped to thickness; edges deburr readily; may be sealed with varnish or epoxy to limit moisture pickup, but plating and anodizing do not apply.

XX chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
cellulose paper (kraft/alpha) reinforcemlayered paper webs, resin-impregnated45 – 6055
processing aids / plasticizer / release 0 – 32
phenol-formaldehyde (resole/novolac) resthermoset matrix, fully cured≥ 38 (balance)—

XXX — frequently asked

What is XXX used for?

XXX is typically used for punched insulating washers, terminal strips and low-voltage PCB substrates. In short: cleanest-punching paper phenolic; pre-FR-4 board material; low-cost punched insulation.

What is the tensile strength of XXX?

XXX has a typical tensile strength of 110 MPa (16 ksi) — weaker than 64% of composite grades. Strength varies by condition: see the 7 listed tempers.

Is XXX easy to machine?

Yes — machinability is rated very good (80/100, better than 85% of composite grades). Cuts, drills and taps easily with carbide tooling and high rake; dust is abrasive and irritating, so use vacuum extraction and back-up plates to avoid exit-side delamination.

Can XXX be welded?

Not weldable — thermoset; join by bolting, riveting or epoxy/phenolic adhesive bonding after abrasion and solvent wipe.

What surface finishes work on XXX?

Sanded or scraped to thickness; edges deburr readily; may be sealed with varnish or epoxy to limit moisture pickup, but plating and anodizing do not apply.

Can XXX be formed, bent or molded?

Supplied fully cured and cannot be post-formed; blanking is done by punching (warm the sheet to 80–130 °C for XX/XXP, room temperature only for XP/XPC/thin stock).

What is the maximum service temperature of XXX?

XXX is rated for continuous use to about 125°C (257 °F), and briefly to 150°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. ASTM D709 — Standard Specification for Laminated Thermosetting Materials — ASTM International (2017)
  2. NEMA LI 1 — Industrial Laminated Thermosetting Products — NEMA (1998)
  3. Paper-phenolic laminate grade data (XX, XXP, XXX, XXXP, XPC) — Norplex-Micarta (2022)
  4. Engineered Materials Handbook, Vol. 2: Engineering Plastics — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.