FabDigitFabDigit

XX XP

Grade

ASTM D709 Grade XX

XP = cold-punching mechanical paper-phenolic

Use where room-temperature punching of gaskets/washers is the priority and electrical values are secondary.

Standard cost $$

Values for the XP condition

Other XX grades and fills

XX is listed in 7 conditions; see the grade overview at XX.

Compare all 7 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Thin cold-punch paper-phenolic
Thin-sheet grade that cold-punches cleanly at 0.8–1.6 mm; historic single-sided PCB substrate.—85295 HRM
XPThis page
Cold-punching mechanical paper-phenolic
Use where room-temperature punching of gaskets/washers is the priority and electrical values are secondary.—90295 HRM
Flame-retardant paper-phenolic, UL 94 V-0
Specify when a V-0 rating is mandatory (consumer electronics, appliance insulation) in a paper-phenolic price class.—951.8100 HRM
Hot-punching paper-phenolic
Choose when thin blanks must be punched at 80–130 °C without cracking, while keeping near-XX insulation values.—1051.7100 HRM
High-electrical punching grade paper-phenolic
Best combination of low dielectric loss and clean punching; classic terminal-board and coil-form material.—1051.6100 HRM
High-humidity electrical paper-phenolic
Pick for radio-frequency / high-humidity insulation where lower loss and lower moisture pickup matter more than strength.—1101.4105 HRM
XXDefault
General-purpose mechanical/electrical paper-phenolic sheet
Default machining grade: best balance of strength, electrical properties and cost for milled or drilled insulation parts.—1201.5105 HRM

What is XX XP?

XX XP is XX in the XP grade — use where room-temperature punching of gaskets/washers is the priority and electrical values are secondary. XX XP has a tensile strength of 90 MPa (13.1 ksi), weaker than 72% of composite grades. Elongation at break is 2% and the elastic modulus is 6.8 GPa (0.986 Msi). XX XP has a density of 1.35 g/cm³ (0.0488 lb/in³), lighter than 75% of composite grades. Its glass-transition temperature is 145°C (293 °F). XX is the default condition FabDigit quotes; XP is available on request or by drawing note.

Advantages

  • Easy to machine — 85/100, better than 90% of composite grades
  • Low embodied carbon — 4.5 kg CO₂/kg, better than 79% of composite grades
  • Lightweight — 1.35 g/cm³ (0.0488 lb/in³), better than 75% of composite grades

Limitations

  • Low fracture toughness — 2 MPa·√m (1.82 ksi·√in), worse than 87% of composite grades
  • Limited service temperature — 110°C (230 °F), worse than 87% of composite grades
  • Degrades in UV without stabilisers — 25/100, worse than 86% of composite grades
  • Absorbs moisture — dry before molding — 1.8%, worse than 85% of composite grades
  • Needs corrosion protection — 56/100, worse than 83% of composite grades

XX XP properties

Typical room-temperature values for XX XP; 18 are specific to this condition. Other listed values are XX reference data and may not represent this condition. Bars are the position among composite grades.

Physical4

XX XP has a density of 1.35 g/cm³ (0.0488 lb/in³), lighter than 75% of composite grades. Its glass-transition temperature is 145°C (293 °F).

Density1.35 g/cm³0.05 lb/in³
Glass Transition (Tg)145°C293 °F
Water Absorption (24 h)1.8%
Water Absorption (Saturation)4.5%

Mechanical12

XX XP has a tensile strength of 90 MPa (13.1 ksi), weaker than 72% of composite grades. Elongation at break is 2% and the elastic modulus is 6.8 GPa (0.986 Msi).

Elastic (Young's) Modulus6.8 GPa0.99 Msi
Poisson's Ratio0.25
Tensile Strength (Ultimate)90 MPa13.1 ksi
Elongation at Break2%
Compressive Strength220 MPa31.9 ksi
Compressive Modulus7 GPa1 Msi
Flexural Strength100 MPa14.5 ksi
Flexural Modulus6.5 GPa0.94 Msi
Shear Strength80 MPa11.6 ksi
Fracture Toughness (K_IC)2 MPa·√m1.8 ksi·√in
Izod Impact, Notched40 J/m0.75 ft·lbf/in
Hardness, Rockwell M95 HRM

Thermal8

XX XP is rated for continuous service to 110°C (230 °F). It conducts heat at 0.25 W/m·K (0.144 BTU/hr·ft·°F), worse than 76% of composite grades. Thermal expansion is 25 µm/m·K (13.9 µin/in·°F).

Thermal Conductivity0.25 W/m·K0.14 BTU/hr·ft·°F
Specific Heat Capacity1,400 J/kg·K0.33 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)25 µm/m·K13.9 µin/in·°F
Max Service Temperature (continuous)110°C230 °F
Min Service Temperature-50°C-58 °F
Flammability (UL 94)HB
Limiting Oxygen Index26%
Max Service Temperature (short-term)150°C302 °F

Electrical7

XX XP is an electrical insulator with a dielectric strength of 10 kV/mm (254 V/mil) and a resistivity of 1×10⁸ Ω·m.

Electrical Resistivity1×10⁸ Ω·m3.94×10¹⁵ µΩ·in
Dielectric Strength10 kV/mm254 V/mil
Dielectric Constant (1 MHz)5
Dissipation Factor (1 MHz)0.04
Volume Resistivity1×10¹² Ω·cm
Surface Resistivity1×10¹¹ Ω
Comparative Tracking Index (CTI)125 V

Chemical & Environmental3

Corrosion resistance is good (56/100), worse than 83% of composite grades. UV resistance is poor.

Corrosion ResistanceGood56/100
UV / Weathering ResistancePoor25/100
Chemical Resistance SummaryGood against oils, greases, transformer fluid, aliphatic solvents and weak acids; attacked by strong alkalis, hot oxidizing acids and steam; hygroscopic paper core swells and loses insulation resistance in prolonged humidity.

Sustainability3

Producing a kilogram of XX XP takes about 80 MJ of energy and emits 4.5 kg of CO₂ — less than 84% of composite grades. Typical recycled content is 0%.

Embodied Energy (primary production)80 MJ/kg34,394 BTU/lb
Embodied Carbon (primary production)4.5 kg CO₂/kg
Typical Recycled Content0%

Manufacturability2

XX XP's machinability is excellent (85/100, better than 90% of composite grades).

MachinabilityExcellent85/100
PolishabilityPoor30/100

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with XX XP

Is XX easy to machine?

Cuts, drills and taps easily with carbide tooling and high rake; dust is abrasive and irritating, so use vacuum extraction and back-up plates to avoid exit-side delamination.

Can XX be welded?

Not weldable — thermoset; join by bolting, riveting or epoxy/phenolic adhesive bonding after abrasion and solvent wipe.

Can XX be formed, bent or molded?

Supplied fully cured and cannot be post-formed; blanking is done by punching (warm the sheet to 80–130 °C for XX/XXP, room temperature only for XP/XPC/thin stock).

What surface finishes work on XX?

Sanded or scraped to thickness; edges deburr readily; may be sealed with varnish or epoxy to limit moisture pickup, but plating and anodizing do not apply.

XX chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
cellulose paper (kraft/alpha) reinforcemlayered paper webs, resin-impregnated45 – 6055
processing aids / plasticizer / release 0 – 32
phenol-formaldehyde (resole/novolac) resthermoset matrix, fully cured≥ 38 (balance)—

XX XP — frequently asked

What is XX XP used for?

XX XP is typically used for punched insulating washers, terminal strips and low-voltage PCB substrates. In short: cleanest-punching paper phenolic; pre-FR-4 board material; low-cost punched insulation.

What is the tensile strength of XX XP?

XX XP has a typical tensile strength of 90 MPa (13.1 ksi) — weaker than 72% of composite grades. Strength varies by condition: see the 7 listed tempers.

Is XX XP easy to machine?

Yes — machinability is rated excellent (85/100, better than 90% of composite grades). Cuts, drills and taps easily with carbide tooling and high rake; dust is abrasive and irritating, so use vacuum extraction and back-up plates to avoid exit-side delamination.

Can XX XP be welded?

Not weldable — thermoset; join by bolting, riveting or epoxy/phenolic adhesive bonding after abrasion and solvent wipe.

What surface finishes work on XX XP?

Sanded or scraped to thickness; edges deburr readily; may be sealed with varnish or epoxy to limit moisture pickup, but plating and anodizing do not apply.

Can XX XP be formed, bent or molded?

Supplied fully cured and cannot be post-formed; blanking is done by punching (warm the sheet to 80–130 °C for XX/XXP, room temperature only for XP/XPC/thin stock).

What is the maximum service temperature of XX XP?

XX XP is rated for continuous use to about 110°C (230 °F), and briefly to 150°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. ASTM D709 — Standard Specification for Laminated Thermosetting Materials — ASTM International (2017)
  2. NEMA LI 1 — Industrial Laminated Thermosetting Products — NEMA (1998)
  3. Paper-phenolic laminate grade data (XX, XXP, XXX, XXXP, XPC) — Norplex-Micarta (2022)
  4. Engineered Materials Handbook, Vol. 2: Engineering Plastics — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.