Titanium · grade comparison

Titanium ERTi-24 and ERTi-7 are both titanium grades. ERTi-24 is the stronger of the two: yield strength 860 MPa (125 ksi) against 330 MPa (47.9 ksi) for ERTi-7, about 161% more; tensile strength follows at 930 MPa (135 ksi) vs 420 MPa (60.9 ksi). In exchange, ERTi-7 is the more ductile: elongation 24% versus 10% for ERTi-24, and ERTi-24 is harder (330 HB vs 155 HB). ERTi-24 is stiffer (114 GPa vs 103 GPa) and ERTi-24 runs hotter in service (350°C vs 315°C continuous). On the shop floor, ERTi-7 machines more easily (fair vs poor) and ERTi-7 welds better (excellent vs very good).

ERTi-24Choose it when strength drives the design, or when the part sees heat.

ERTi-7Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

ERTi-24 vs ERTi-7: properties

ERTi-24ERTi-7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

114 GPa16.5 Msi
103 GPa14.9 Msi

Shear Modulus

44 GPa6.4 Msi
45 GPa6.5 Msi

Tensile Strength (Ultimate)

930 MPa135 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

860 MPa125 ksi
330 MPa47.9 ksi

Elongation at Break

10%
24%

Reduction in Area

25%
45%

Compressive Strength

1,070 MPa155 ksi
350 MPa50.8 ksi

Shear Strength

580 MPa84.1 ksi
275 MPa39.9 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
210 MPa30.5 ksi

Fracture Toughness (K_IC)

65 MPa·√m59.2 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

330 HB
155 HB

Hardness, Rockwell C

34 HRC
—

Hardness, Vickers

350 HV
165 HV

Hardness, Rockwell B

—
80 HRB

Same in both: Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Density

4.43 g/cm³0.16 lb/in³
4.51 g/cm³0.16 lb/in³

Melting Point (Solidus)

1,604°C2,919 °F
1,660°C3,020 °F

Liquidus Temperature

1,660°C3,020 °F
1,670°C3,038 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

6.7 W/m·K3.9 BTU/hr·ft·°F
16.4 W/m·K9.5 BTU/hr·ft·°F

Specific Heat Capacity

560 J/kg·K0.13 BTU/lb·°F
523 J/kg·K0.12 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

8.7 µm/m·K4.8 µin/in·°F
8.6 µm/m·K4.8 µin/in·°F

Latent Heat of Fusion

365 J/g157 BTU/lb
325 J/g140 BTU/lb

Max Service Temperature (continuous)

350°C662 °F
315°C599 °F

Same in both: Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1 % IACS
3.1 % IACS

Electrical Resistivity

1.7×10⁻⁶ Ω·m66.9 µΩ·in
5.6×10⁻⁷ Ω·m22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.05 V
-0.1 V

Corrosion Resistance

94 / 100
95 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
35%

Weldability

80 / 100
92 / 100

Formability (cold)

30 / 100
75 / 100

Castability

55 / 100
—

Brazeability / Solderability

40 / 100
45 / 100

Same in both: Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

700 MJ/kg300,946 BTU/lb
720 MJ/kg309,545 BTU/lb

Embodied Carbon (primary production)

42 kg CO₂/kg
48 kg CO₂/kg

Embodied Water

900 L/kg108 gal/lb
500 L/kg59.9 gal/lb

Typical Recycled Content

15%
10%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

210 kN·m/kg
93 kN·m/kg

Specific Stiffness (E / density)

25.7 MN·m/kg
22.8 MN·m/kg

Modulus of Resilience

3,244 kJ/m³
529 kJ/m³

Thermal Diffusivity

2.7 mm²/s
7 mm²/s

Thermal Shock Resistance Index

6
8

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleERTi-7ERTi-24

Manufacturing and finishing

CapabilityERTi-24ERTi-7
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 1 finish: Plasma Spray.

ERTi-24 vs ERTi-7 — frequently asked

Is ERTi-24 stronger than ERTi-7?

Yes. ERTi-24 has a typical yield strength of 860 MPa (125 ksi) against 330 MPa (47.9 ksi) for ERTi-7 — about 161% more. Tensile strength is 930 MPa (135 ksi) vs 420 MPa (60.9 ksi).

Which is cheaper, ERTi-24 or ERTi-7?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, ERTi-24 or ERTi-7?

ERTi-7. Its machinability rates fair (40/100) against poor (20/100) for ERTi-24; for welding the order is ERTi-7 first (excellent, 92/100) then ERTi-24 (very good, 80/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in ERTi-24 and ERTi-7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.