FabDigitFabDigit

Steel S700MC vs X70

Steel · grade comparison

Steel S700MC and X70 are both steel grades. S700MC is the stronger of the two: yield strength 740 MPa (107 ksi) against 520 MPa (75.4 ksi) for X70, about 42% more; tensile strength follows at 810 MPa (117 ksi) vs 610 MPa (88.5 ksi). In exchange, X70 is the more ductile: elongation 28% versus 14% for S700MC, and S700MC is harder (245 HB vs 200 HB). S700MC runs hotter in service (300°C vs 250°C continuous) and X70 conducts heat better (45 W/m·K vs 40 W/m·K). On the shop floor, X70 machines more easily (good vs fair) and X70 sits in a lower cost tier (budget, $) than S700MC (standard, $$).

S700MCChoose it when strength drives the design, or when the part sees heat.

X70Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

S700MC vs X70: properties

S700MCX70

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

210 GPa30.5 Msi
207 GPa30 Msi

Shear Modulus

81 GPa11.7 Msi
80 GPa11.6 Msi

Poisson's Ratio

0.3
0.29

Tensile Strength (Ultimate)

810 MPa117 ksi
610 MPa88.5 ksi

Yield Strength (0.2% offset)

740 MPa107 ksi
520 MPa75.4 ksi

Elongation at Break

14%
28%

Reduction in Area

55%
65%

Compressive Strength

740 MPa107 ksi
520 MPa75.4 ksi

Shear Strength

490 MPa71.1 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
270 MPa39.2 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
190 MPa·√m173 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
250 J184 ft·lbf

Hardness, Brinell

245 HB
200 HB

Hardness, Rockwell B

100 HRB
93 HRB

Hardness, Rockwell C

23 HRC
—

Hardness, Vickers

255 HV
210 HV

Same in both: Bulk Modulus 160 GPa23.2 Msi

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,460°C2,660 °F
1,490°C2,714 °F

Liquidus Temperature

1,510°C2,750 °F
1,520°C2,768 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

40 W/m·K23.1 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
250°C482 °F

Min Service Temperature

-40°C-40 °F
-45°C-49 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
10 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.62 V
-0.65 V

Same in both: Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
60%

Weldability

85 / 100
88 / 100

Formability (cold)

65 / 100
68 / 100

Brazeability / Solderability

50 / 100
55 / 100

Polishability

50 / 100
45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

2 kg CO₂/kg
2.1 kg CO₂/kg

Embodied Water

40 L/kg4.8 gal/lb
45 L/kg5.4 gal/lb

Typical Recycled Content

25%
20%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

103 kN·m/kg
78 kN·m/kg

Specific Stiffness (E / density)

26.8 MN·m/kg
26.4 MN·m/kg

Modulus of Resilience

1,304 kJ/m³
653 kJ/m³

Thermal Diffusivity

10.8 mm²/s
12.2 mm²/s

Thermal Shock Resistance Index

13
11

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS700MCX70

Manufacturing and finishing

CapabilityS700MCX70
Sheet metalYes—
Default conditionTMCP—
Relative cost$$ Standard$ Budget
Min. machined wall——
Best machined surface——
Black OxideYes—
CerakoteYes—
Chrome PlatingYes—
E-CoatingYes—
Hot-Dip GalvanizingYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—
Powder CoatingYes—
Tin PlatingYes—
Zinc PlatingYes—
Zinc-Flake (Dip-Spin) CoatingYes—
Zinc-Nickel PlatingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

S700MC vs X70 — frequently asked

Is S700MC stronger than X70?

Yes. S700MC has a typical yield strength of 740 MPa (107 ksi) against 520 MPa (75.4 ksi) for X70 — about 42% more. Tensile strength is 810 MPa (117 ksi) vs 610 MPa (88.5 ksi).

Which is cheaper, S700MC or X70?

X70 is the lower-cost material: it sits in the budget tier ($) while S700MC is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, S700MC or X70?

X70. Its machinability rates good (55/100) against fair (45/100) for S700MC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S700MC and X70 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.