FabDigitFabDigit

Steel S5 As-Quenched vs S5 Normalized

Steel · S5 temper comparison

S5 As-Quenched and S5 Normalized are two conditions of the same steel grade, S5: As-Quenched (870 °C oil quench, untempered) versus Normalized. The chemistry is identical, so every difference below comes from the condition. S5 As-Quenched is the stronger of the two: yield strength 2,050 MPa (297 ksi) against 800 MPa (116 ksi) for S5 Normalized, about 156% more; tensile strength follows at 2,400 MPa (348 ksi) vs 1,250 MPa (181 ksi). In exchange, S5 Normalized is the more ductile: elongation 10% versus 1% for S5 As-Quenched, and S5 As-Quenched is harder (690 HB vs 375 HB). S5 Normalized runs hotter in service (250°C vs 150°C continuous) and S5 Normalized conducts heat better (25 W/m·K vs 21 W/m·K). On the shop floor, S5 Normalized machines more easily (poor vs not recommended) and S5 Normalized welds better (poor vs not recommended).

S5 As-QuenchedChoose it when strength drives the design.

S5 NormalizedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S5 As-Quenched vs S5 Normalized: properties

S5 As-QuenchedS5 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

2,400 MPa348 ksi
1,250 MPa181 ksi

Yield Strength (0.2% offset)

2,050 MPa297 ksi
800 MPa116 ksi

Elongation at Break

1%
10%

Reduction in Area

2%
30%

Compressive Strength

2,700 MPa392 ksi
840 MPa122 ksi

Shear Strength

1,450 MPa210 ksi
750 MPa109 ksi

Fatigue Strength (Endurance Limit)

700 MPa102 ksi
560 MPa81.2 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

690 HB
375 HB

Hardness, Vickers

790 HV
395 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 95 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.76 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

21 W/m·K12.1 BTU/hr·ft·°F
25 W/m·K14.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.5 % IACS
3.8 % IACS

Electrical Resistivity

5×10⁻⁷ Ω·m19.7 µΩ·in
4.7×10⁻⁷ Ω·m18.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

10 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

5%
30%

Weldability

5 / 100
15 / 100

Formability (cold)

2 / 100
10 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS5

S5 As-Quenched vs S5 Normalized — frequently asked

Is S5 As-Quenched stronger than S5 Normalized?

Yes. S5 As-Quenched has a typical yield strength of 2,050 MPa (297 ksi) against 800 MPa (116 ksi) for S5 Normalized — about 156% more. Tensile strength is 2,400 MPa (348 ksi) vs 1,250 MPa (181 ksi).

Which condition does FabDigit quote by default, As-Quenched or Normalized?

Annealed is the default S5 condition in the FabDigit quote flow (neither As-Quenched nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S5 As-Quenched or S5 Normalized?

S5 Normalized. Its machinability rates poor (28/100) against not recommended (5/100) for S5 As-Quenched; for welding the order is S5 Normalized first (poor, 15/100) then S5 As-Quenched (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S5 As-Quenched and S5 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.