FabDigitFabDigit

Steel S5 As-Quenched vs S5 Hardened & Tempered

Steel · S5 temper comparison

S5 As-Quenched and S5 Hardened & Tempered are two conditions of the same steel grade, S5: As-Quenched (870 °C oil quench, untempered) versus Hardened & Tempered (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. S5 As-Quenched is the stronger of the two: yield strength 2,050 MPa (297 ksi) against 1,850 MPa (268 ksi) for S5 Hardened & Tempered, about 11% more; tensile strength follows at 2,400 MPa (348 ksi) vs 2,150 MPa (312 ksi). In exchange, S5 Hardened & Tempered is the more ductile: elongation 4% versus 1% for S5 As-Quenched, and S5 As-Quenched is harder (690 HB vs 215 HB). S5 Hardened & Tempered runs hotter in service (175°C vs 150°C continuous) and S5 Hardened & Tempered conducts heat better (24 W/m·K vs 21 W/m·K). On the shop floor, S5 Hardened & Tempered machines more easily (fair vs not recommended) and S5 Hardened & Tempered welds better (poor vs not recommended).

S5 As-QuenchedChoose it when strength drives the design.

S5 Hardened & TemperedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S5 As-Quenched vs S5 Hardened & Tempered: properties

S5 As-QuenchedS5 Hardened & Tempered

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

2,400 MPa348 ksi
2,150 MPa312 ksi

Yield Strength (0.2% offset)

2,050 MPa297 ksi
1,850 MPa268 ksi

Elongation at Break

1%
4%

Reduction in Area

2%
12%

Compressive Strength

2,700 MPa392 ksi
2,800 MPa406 ksi

Shear Strength

1,450 MPa210 ksi
1,290 MPa187 ksi

Fatigue Strength (Endurance Limit)

700 MPa102 ksi
780 MPa113 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

690 HB
215 HB

Hardness, Vickers

790 HV
680 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 95 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.76 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

21 W/m·K12.1 BTU/hr·ft·°F
24 W/m·K13.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.5 % IACS
4 % IACS

Electrical Resistivity

5×10⁻⁷ Ω·m19.7 µΩ·in
4.5×10⁻⁷ Ω·m17.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

10 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
50 / 100

Weldability

5 / 100
25 / 100

Formability (cold)

2 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 5% · Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS5

S5 As-Quenched vs S5 Hardened & Tempered — frequently asked

Is S5 As-Quenched stronger than S5 Hardened & Tempered?

Yes. S5 As-Quenched has a typical yield strength of 2,050 MPa (297 ksi) against 1,850 MPa (268 ksi) for S5 Hardened & Tempered — about 11% more. Tensile strength is 2,400 MPa (348 ksi) vs 2,150 MPa (312 ksi).

Which condition does FabDigit quote by default, As-Quenched or Hardened & Tempered?

Annealed is the default S5 condition in the FabDigit quote flow (neither As-Quenched nor Hardened & Tempered). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S5 As-Quenched or S5 Hardened & Tempered?

S5 Hardened & Tempered. Its machinability rates fair (50/100) against not recommended (5/100) for S5 As-Quenched; for welding the order is S5 Hardened & Tempered first (poor, 25/100) then S5 As-Quenched (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S5 As-Quenched and S5 Hardened & Tempered side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.