FabDigitFabDigit

Steel S5 Annealed vs S5 Normalized

Steel · S5 temper comparison

S5 Annealed and S5 Normalized are two conditions of the same steel grade, S5: Annealed versus Normalized. The chemistry is identical, so every difference below comes from the condition. S5 Normalized is the stronger of the two: yield strength 800 MPa (116 ksi) against 440 MPa (63.8 ksi) for S5 Annealed, about 82% more; tensile strength follows at 1,250 MPa (181 ksi) vs 725 MPa (105 ksi). In exchange, S5 Annealed is the more ductile: elongation 25% versus 10% for S5 Normalized, and S5 Normalized is harder (375 HB vs 215 HB). S5 Annealed runs hotter in service (400°C vs 250°C continuous). On the shop floor, S5 Annealed machines more easily (fair vs poor) and S5 Annealed welds better (25 vs 15 out of 100).

S5 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S5 NormalizedChoose it when strength drives the design.

S5 Annealed vs S5 Normalized: properties

S5 AnnealedS5 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
1,250 MPa181 ksi

Yield Strength (0.2% offset)

440 MPa63.8 ksi
800 MPa116 ksi

Elongation at Break

25%
10%

Reduction in Area

45%
30%

Compressive Strength

460 MPa66.7 ksi
840 MPa122 ksi

Shear Strength

440 MPa63.8 ksi
750 MPa109 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
560 MPa81.2 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

215 HB
375 HB

Hardness, Vickers

225 HV
395 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 95 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.76 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

24 W/m·K13.9 BTU/hr·ft·°F
25 W/m·K14.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
250°C482 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4 % IACS
3.8 % IACS

Electrical Resistivity

4.5×10⁻⁷ Ω·m17.7 µΩ·in
4.7×10⁻⁷ Ω·m18.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
30%

Weldability

25 / 100
15 / 100

Formability (cold)

30 / 100
10 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS5

S5 Annealed vs S5 Normalized — frequently asked

Is S5 Normalized stronger than S5 Annealed?

Yes. S5 Normalized has a typical yield strength of 800 MPa (116 ksi) against 440 MPa (63.8 ksi) for S5 Annealed — about 82% more. Tensile strength is 1,250 MPa (181 ksi) vs 725 MPa (105 ksi).

Which condition does FabDigit quote by default, Annealed or Normalized?

Annealed is the default S5 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S5 Annealed or S5 Normalized?

S5 Annealed. Its machinability rates fair (50/100) against poor (28/100) for S5 Normalized; for welding the order is S5 Annealed first (poor, 25/100) then S5 Normalized (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S5 Annealed and S5 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.