FabDigitFabDigit

Steel GE200-F vs GE200 +NT

Steel · GE200 temper comparison

GE200-F and GE200 +NT are two conditions of the same steel grade, GE200: F (as fabricated) versus +NT (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. GE200 +NT is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 220 MPa (31.9 ksi) for GE200-F, about 7% more. GE200 +NT is the more ductile: elongation 29% versus 22% for GE200-F, and GE200-F is harder (130 HB vs 122 HB).

GE200 +NTChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

GE200-F vs GE200 +NT: properties

GE200-FGE200 +NT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Yield Strength (0.2% offset)

220 MPa31.9 ksi
235 MPa34.1 ksi

Elongation at Break

22%
29%

Reduction in Area

30%
46%

Compressive Strength

220 MPa31.9 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
175 MPa25.4 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

130 HB
122 HB

Hardness, Rockwell B

72 HRB
68 HRB

Hardness, Vickers

137 HV
128 HV

Same in both: Elastic (Young's) Modulus 208 GPa30.2 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Tensile Strength (Ultimate) 430 MPa62.4 ksi · Shear Strength 260 MPa37.7 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,515°C2,759 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
72%

Weldability

84 / 100
88 / 100

Formability (cold)

15 / 100
22 / 100

Same in both: Castability 78 / 100 · Brazeability / Solderability 60 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleGE200

GE200-F vs GE200 +NT — frequently asked

Is GE200 +NT stronger than GE200-F?

Yes. GE200 +NT has a typical yield strength of 235 MPa (34.1 ksi) against 220 MPa (31.9 ksi) for GE200-F — about 7% more. Tensile strength is 430 MPa (62.4 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, F or +NT?

+N is the default GE200 condition in the FabDigit quote flow (neither F nor +NT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, GE200-F or GE200 +NT?

GE200 +NT, by a small margin. Both rate good for machinability — 68/100 against 60/100 for GE200-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in GE200-F and GE200 +NT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.