FabDigitFabDigit

Steel 49MnVS3 Induction Hardened vs 49MnVS3 Normalized

Steel · 49MnVS3 temper comparison

49MnVS3 Induction Hardened and 49MnVS3 Normalized are two conditions of the same steel grade, 49MnVS3: Induction Hardened versus Normalized. The chemistry is identical, so every difference below comes from the condition. 49MnVS3 Induction Hardened is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 490 MPa (71.1 ksi) for 49MnVS3 Normalized, about 18% more; tensile strength follows at 900 MPa (131 ksi) vs 820 MPa (119 ksi). In exchange, 49MnVS3 Normalized is the more ductile: elongation 16% versus 10% for 49MnVS3 Induction Hardened, and 49MnVS3 Induction Hardened is harder (265 HB vs 235 HB). 49MnVS3 Normalized runs hotter in service (350°C vs 180°C continuous). On the shop floor, 49MnVS3 Normalized machines more easily (good vs poor) and 49MnVS3 Normalized welds better (poor vs not recommended).

49MnVS3 Induction HardenedChoose it when strength drives the design.

49MnVS3 NormalizedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

49MnVS3 Induction Hardened vs 49MnVS3 Normalized: properties

49MnVS3 Induction Hardened49MnVS3 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

900 MPa131 ksi
820 MPa119 ksi

Yield Strength (0.2% offset)

580 MPa84.1 ksi
490 MPa71.1 ksi

Elongation at Break

10%
16%

Reduction in Area

22%
30%

Compressive Strength

1,900 MPa276 ksi
490 MPa71.1 ksi

Shear Strength

540 MPa78.3 ksi
490 MPa71.1 ksi

Fatigue Strength (Endurance Limit)

520 MPa75.4 ksi
365 MPa52.9 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

265 HB
235 HB

Hardness, Rockwell C

57 HRC
21 HRC

Hardness, Vickers

650 HV
247 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

43 W/m·K24.8 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
350°C662 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.2 % IACS
8.6 % IACS

Electrical Resistivity

2.1×10⁻⁷ Ω·m8.27 µΩ·in
2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

15 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
63%

Weldability

10 / 100
25 / 100

Formability (cold)

5 / 100
28 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale49MnVS3

49MnVS3 Induction Hardened vs 49MnVS3 Normalized — frequently asked

Is 49MnVS3 Induction Hardened stronger than 49MnVS3 Normalized?

Yes. 49MnVS3 Induction Hardened has a typical yield strength of 580 MPa (84.1 ksi) against 490 MPa (71.1 ksi) for 49MnVS3 Normalized — about 18% more. Tensile strength is 900 MPa (131 ksi) vs 820 MPa (119 ksi).

Which condition does FabDigit quote by default, Induction Hardened or Normalized?

As Forged is the default 49MnVS3 condition in the FabDigit quote flow (neither Induction Hardened nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 49MnVS3 Induction Hardened or 49MnVS3 Normalized?

49MnVS3 Normalized. Its machinability rates good (60/100) against poor (15/100) for 49MnVS3 Induction Hardened; for welding the order is 49MnVS3 Normalized first (poor, 25/100) then 49MnVS3 Induction Hardened (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 49MnVS3 Induction Hardened and 49MnVS3 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.