FabDigitFabDigit

Steel 30KhGSL vs WC4

Steel · grade comparison

Steel 30KhGSL and WC4 are both steel grades. 30KhGSL is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 335 MPa (48.6 ksi) for WC4, about 28% more; tensile strength follows at 650 MPa (94.3 ksi) vs 545 MPa (79 ksi). In exchange, WC4 is the more ductile: elongation 24% versus 15% for 30KhGSL, and 30KhGSL is harder (207 HB vs 163 HB). WC4 runs hotter in service (540°C vs 400°C continuous). On the shop floor, WC4 machines more easily (good vs fair) and WC4 welds better (good vs fair).

30KhGSLChoose it when strength drives the design.

WC4Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

30KhGSL vs WC4: properties

30KhGSLWC4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
200 GPa29 Msi

Shear Modulus

80 GPa11.6 Msi
78 GPa11.3 Msi

Bulk Modulus

165 GPa23.9 Msi
160 GPa23.2 Msi

Tensile Strength (Ultimate)

650 MPa94.3 ksi
545 MPa79 ksi

Yield Strength (0.2% offset)

430 MPa62.4 ksi
335 MPa48.6 ksi

Elongation at Break

15%
24%

Reduction in Area

28%
50%

Compressive Strength

440 MPa63.8 ksi
340 MPa49.3 ksi

Shear Strength

420 MPa60.9 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

270 MPa39.2 ksi
235 MPa34.1 ksi

Fracture Toughness (K_IC)

65 MPa·√m59.2 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
48 J35.4 ft·lbf

Hardness, Brinell

207 HB
163 HB

Hardness, Rockwell C

18 HRC
—

Hardness, Vickers

218 HV
—

Hardness, Rockwell B

—
85 HRB

Same in both: Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Density

7.85 g/cm³0.28 lb/in³
7.83 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,495°C2,723 °F
1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

11.5 µm/m·K6.4 µin/in·°F
12.3 µm/m·K6.8 µin/in·°F

Latent Heat of Fusion

250 J/g107 BTU/lb
270 J/g116 BTU/lb

Max Service Temperature (continuous)

400°C752 °F
540°C1,004 °F

Min Service Temperature

-40°C-40 °F
-29°C-20 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

12 / 100
14 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
60%

Weldability

40 / 100
55 / 100

Formability (cold)

15 / 100
20 / 100

Castability

58 / 100
70 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

27 MJ/kg11,608 BTU/lb
26 MJ/kg11,178 BTU/lb

Embodied Carbon (primary production)

2.1 kg CO₂/kg
2 kg CO₂/kg

Embodied Water

45 L/kg5.4 gal/lb
55 L/kg6.6 gal/lb

Typical Recycled Content

70%
75%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

83 kN·m/kg
70 kN·m/kg

Specific Stiffness (E / density)

26.1 MN·m/kg
25.5 MN·m/kg

Modulus of Resilience

451 kJ/m³
281 kJ/m³

Thermal Diffusivity

10.3 mm²/s
11.4 mm²/s

Thermal Shock Resistance Index

10
9

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleWC430KhGSL

Manufacturing and finishing

Capability30KhGSLWC4
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall——
Best machined surface——

Both take the same 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

30KhGSL vs WC4 — frequently asked

Is 30KhGSL stronger than WC4?

Yes. 30KhGSL has a typical yield strength of 430 MPa (62.4 ksi) against 335 MPa (48.6 ksi) for WC4 — about 28% more. Tensile strength is 650 MPa (94.3 ksi) vs 545 MPa (79 ksi).

Which is cheaper, 30KhGSL or WC4?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 30KhGSL or WC4?

WC4. Its machinability rates good (58/100) against fair (48/100) for 30KhGSL; for welding the order is WC4 first (good, 55/100) then 30KhGSL (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30KhGSL and WC4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.