FabDigitFabDigit

Steel 1117 vs 1118

Steel · grade comparison

Steel 1117 and 1118 are both steel grades. 1118 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 235 MPa (34.1 ksi) for 1117, about 91% more; tensile strength follows at 525 MPa (76.1 ksi) vs 425 MPa (61.6 ksi). In exchange, 1117 is the more ductile: elongation 33% versus 15% for 1118, and 1118 is harder (149 HB vs 121 HB). On the shop floor, 1118 machines more easily (excellent vs very good).

1117Choose it when the part is bent, formed or impact-loaded.

1118Choose it when strength drives the design, or when the part is machined in volume.

1117 vs 1118: properties

11171118

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

425 MPa61.6 ksi
525 MPa76.1 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
450 MPa65.3 ksi

Elongation at Break

33%
15%

Reduction in Area

58%
40%

Shear Strength

320 MPa46.4 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

121 HB
149 HB

Hardness, Rockwell B

68 HRB
80 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Density

7.87 g/cm³0.28 lb/in³
7.85 g/cm³0.28 lb/in³

Same in both: Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
51.9 W/m·K30 BTU/hr·ft·°F

Specific Heat Capacity

470 J/kg·K0.11 BTU/lb·°F
486 J/kg·K0.12 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.7 µm/m·K6.5 µin/in·°F
11.9 µm/m·K6.6 µin/in·°F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Same in both: Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
85 / 100

Weldability

50 / 100
45 / 100

Formability (cold)

60 / 100
50 / 100

Brazeability / Solderability

65 / 100
70 / 100

Polishability

45 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 91%

Sustainability

Primary-production footprint per kilogram.

Embodied Water

45 L/kg5.4 gal/lb
60 L/kg7.2 gal/lb

Typical Recycled Content

30%
35%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

54 kN·m/kg
67 kN·m/kg

Specific Stiffness (E / density)

25.4 MN·m/kg
25.5 MN·m/kg

Modulus of Resilience

138 kJ/m³
506 kJ/m³

Thermal Diffusivity

13.8 mm²/s
13.6 mm²/s

Thermal Shock Resistance Index

9
11

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale11171118

Manufacturing and finishing

Capability11171118
CNC machiningYes—
Default conditionHR—
Relative cost$ Budget$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1117 vs 1118 — frequently asked

Is 1118 stronger than 1117?

Yes. 1118 has a typical yield strength of 450 MPa (65.3 ksi) against 235 MPa (34.1 ksi) for 1117 — about 91% more. Tensile strength is 525 MPa (76.1 ksi) vs 425 MPa (61.6 ksi).

Which is cheaper, 1117 or 1118?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 1117 or 1118?

1118. Its machinability rates excellent (85/100) against very good (70/100) for 1117; for welding the order is 1117 first (fair, 50/100) then 1118 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1117 and 1118 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.