FabDigitFabDigit

Steel 1112-ANN vs 1112 NORM

Steel · 1112 temper comparison

1112-ANN and 1112 NORM are two conditions of the same steel grade, 1112: ANN (annealed) versus NORM (normalized). The chemistry is identical, so every difference below comes from the condition. 1112 NORM is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 230 MPa (33.4 ksi) for 1112-ANN, about 20% more; tensile strength follows at 450 MPa (65.3 ksi) vs 395 MPa (57.3 ksi). In exchange, 1112-ANN is the more ductile: elongation 30% versus 27% for 1112 NORM, and 1112 NORM is harder (130 HB vs 110 HB).

1112-ANNChoose it when the part is bent, formed or impact-loaded.

1112 NORMChoose it when strength drives the design.

1112-ANN vs 1112 NORM: properties

1112-ANN1112 NORM

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
275 MPa39.9 ksi

Elongation at Break

30%
27%

Reduction in Area

55%
48%

Shear Strength

240 MPa34.8 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
215 MPa31.2 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

110 HB
130 HB

Hardness, Rockwell B

62 HRB
72 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.5 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
82 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
90%

Formability (cold)

50 / 100
55 / 100

Same in both: Weldability 28 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1112

1112-ANN vs 1112 NORM — frequently asked

Is 1112 NORM stronger than 1112-ANN?

Yes. 1112 NORM has a typical yield strength of 275 MPa (39.9 ksi) against 230 MPa (33.4 ksi) for 1112-ANN — about 20% more. Tensile strength is 450 MPa (65.3 ksi) vs 395 MPa (57.3 ksi).

Which condition does FabDigit quote by default, ANN or NORM?

CD is the default 1112 condition in the FabDigit quote flow (neither ANN nor NORM). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1112-ANN over 1112 NORM?

Pick 1112-ANN when the part is bent, formed or impact-loaded. Pick 1112 NORM when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1112-ANN and 1112 NORM side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.