FabDigitFabDigit

Steel 1040 vs 56Mn4

Steel · grade comparison

Steel 1040 and 56Mn4 are both steel grades. 56Mn4 is the stronger of the two: tensile strength 690 MPa (100 ksi) against 620 MPa (89.9 ksi) for 1040, about 11% more. In exchange, 1040 is the more ductile: elongation 25% versus 15% for 56Mn4. 1040 runs hotter in service (425°C vs 350°C continuous) and 1040 conducts electricity better (10 % IACS vs 8.5 % IACS). On the shop floor, 1040 welds better (fair vs poor).

1040Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

56Mn4Choose it when strength drives the design.

1040 vs 56Mn4: properties

104056Mn4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
207 GPa30 Msi

Tensile Strength (Ultimate)

620 MPa89.9 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
400 MPa58 ksi

Elongation at Break

25%
15%

Reduction in Area

50%
38%

Compressive Strength

415 MPa60.2 ksi
400 MPa58 ksi

Shear Strength

385 MPa55.8 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

201 HB
205 HB

Hardness, Rockwell B

93 HRB
94 HRB

Hardness, Vickers

210 HV
215 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,425°C2,597 °F
1,420°C2,588 °F

Liquidus Temperature

1,495°C2,723 °F
1,480°C2,696 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Specific Heat Capacity

486 J/kg·K0.12 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.5 µm/m·K6.4 µin/in·°F
12.3 µm/m·K6.8 µin/in·°F

Latent Heat of Fusion

247 J/g106 BTU/lb
250 J/g107 BTU/lb

Max Service Temperature (continuous)

425°C797 °F
350°C662 °F

Same in both: Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10 % IACS
8.5 % IACS

Electrical Resistivity

1.71×10⁻⁷ Ω·m6.73 µΩ·in
2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.6 V

Same in both: Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

45 / 100
25 / 100

Brazeability / Solderability

60 / 100
55 / 100

Castability

—
55 / 100

Same in both: Formability (cold) 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

2.1 kg CO₂/kg
1.9 kg CO₂/kg

Embodied Water

50 L/kg6 gal/lb
42 L/kg5 gal/lb

Typical Recycled Content

25%
30%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

79 kN·m/kg
88 kN·m/kg

Specific Stiffness (E / density)

26.1 MN·m/kg
26.4 MN·m/kg

Modulus of Resilience

420 kJ/m³
386 kJ/m³

Thermal Diffusivity

13.4 mm²/s
12.5 mm²/s

Thermal Shock Resistance Index

13
12

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale104056Mn4

Manufacturing and finishing

Capability104056Mn4
CNC machiningYes—
Sheet metalYes—
Default conditionHR—
Relative cost$ Budget$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1040 vs 56Mn4 — frequently asked

Is 56Mn4 stronger than 1040?

Yes. 56Mn4 has a typical tensile strength of 690 MPa (100 ksi) against 620 MPa (89.9 ksi) for 1040 — about 11% more.

Which is cheaper, 1040 or 56Mn4?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 1040 or 56Mn4?

1040. Its machinability rates good (55/100) against fair (48/100) for 56Mn4; for welding the order is 1040 first (fair, 45/100) then 56Mn4 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1040 and 56Mn4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.