FabDigitFabDigit

Steel 1040 vs 1045

Steel · grade comparison

Steel 1040 and 1045 are both steel grades, both medium carbon steel. 1045 is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 415 MPa (60.2 ksi) for 1040, about 28% more. In exchange, 1040 is the more ductile: elongation 25% versus 12% for 1045, and 1040 is harder (201 HB vs 179 HB).

1040Choose it when the part is bent, formed or impact-loaded.

1045Choose it when strength drives the design.

1040 vs 1045: properties

10401045

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
625 MPa90.6 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
530 MPa76.9 ksi

Elongation at Break

25%
12%

Reduction in Area

50%
35%

Compressive Strength

415 MPa60.2 ksi
540 MPa78.3 ksi

Shear Strength

385 MPa55.8 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

201 HB
179 HB

Hardness, Rockwell B

93 HRB
89 HRB

Hardness, Vickers

210 HV
188 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,425°C2,597 °F
1,420°C2,588 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
49 W/m·K28.3 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

11.5 µm/m·K6.4 µin/in·°F
11.7 µm/m·K6.5 µin/in·°F

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10 % IACS
10.8 % IACS

Electrical Resistivity

1.71×10⁻⁷ Ω·m6.73 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

10 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
57%

Formability (cold)

45 / 100
35 / 100

Brazeability / Solderability

60 / 100
65 / 100

Castability

—
55 / 100

Same in both: Weldability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

2.1 kg CO₂/kg
2 kg CO₂/kg

Embodied Water

50 L/kg6 gal/lb
55 L/kg6.6 gal/lb

Typical Recycled Content

25%
35%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

79 kN·m/kg
80 kN·m/kg

Modulus of Resilience

420 kJ/m³
685 kJ/m³

Thermal Diffusivity

13.4 mm²/s
12.8 mm²/s

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg · Thermal Shock Resistance Index 13

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale10401045

Manufacturing and finishing

Capability10401045
Casting & forging—Yes
Default conditionHRCD
Relative cost$ Budget$ Budget
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining and Sheet metal. Both take the same 38 finishes: AlCrN, AlTiN, Black Oxide, CVD Al2O3, CVD TiCN, CVD TiN, Cerakote, Chrome Plating, Copper Plating, CrN, DLC, E-Coating and 26 more.

1040 vs 1045 — frequently asked

Is 1045 stronger than 1040?

Yes. 1045 has a typical yield strength of 530 MPa (76.9 ksi) against 415 MPa (60.2 ksi) for 1040 — about 28% more. Tensile strength is 625 MPa (90.6 ksi) vs 620 MPa (89.9 ksi).

Which is cheaper, 1040 or 1045?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose 1040 over 1045?

Pick 1040 when the part is bent, formed or impact-loaded. Pick 1045 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1040 and 1045 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.