FabDigitFabDigit

Steel 1037 vs 1040

Steel · grade comparison

Steel 1037 and 1040 are both steel grades. 1040 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 282 MPa (40.9 ksi) for 1037, about 47% more; tensile strength follows at 620 MPa (89.9 ksi) vs 510 MPa (74 ksi). 1040 is harder — 201 HB against 143 HB for 1037 — which matters for wear surfaces and threads. On the shop floor, 1037 welds better (good vs fair) and 1037 forms better (good vs fair).

1037Choose it when it will be welded.

1040Choose it when strength drives the design, or when surface hardness matters.

1037 vs 1040: properties

10371040

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
205 GPa29.7 Msi

Bulk Modulus

140 GPa20.3 Msi
160 GPa23.2 Msi

Tensile Strength (Ultimate)

510 MPa74 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

282 MPa40.9 ksi
415 MPa60.2 ksi

Elongation at Break

26%
25%

Reduction in Area

47%
50%

Compressive Strength

285 MPa41.3 ksi
415 MPa60.2 ksi

Shear Strength

340 MPa49.3 ksi
385 MPa55.8 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
290 MPa42.1 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

143 HB
201 HB

Hardness, Rockwell B

79 HRB
93 HRB

Hardness, Vickers

150 HV
210 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in

Physical

Density and transition temperatures.

Liquidus Temperature

1,500°C2,732 °F
1,495°C2,723 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

50 W/m·K28.9 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

11.7 µm/m·K6.5 µin/in·°F
11.5 µm/m·K6.4 µin/in·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
10 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.71×10⁻⁷ Ω·m6.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
55 / 100

Weldability

58 / 100
45 / 100

Formability (cold)

55 / 100
45 / 100

Brazeability / Solderability

65 / 100
60 / 100

Polishability

50 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 60%

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

1.9 kg CO₂/kg
2.1 kg CO₂/kg

Embodied Water

40 L/kg4.8 gal/lb
50 L/kg6 gal/lb

Typical Recycled Content

30%
25%

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

65 kN·m/kg
79 kN·m/kg

Specific Stiffness (E / density)

25.5 MN·m/kg
26.1 MN·m/kg

Modulus of Resilience

199 kJ/m³
420 kJ/m³

Thermal Diffusivity

13.1 mm²/s
13.4 mm²/s

Thermal Shock Resistance Index

11
13

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale10401037

Manufacturing and finishing

Capability10371040
CNC machining—Yes
Sheet metal—Yes
Default condition—HR
Relative cost$ Budget$ Budget
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1037 vs 1040 — frequently asked

Is 1040 stronger than 1037?

Yes. 1040 has a typical yield strength of 415 MPa (60.2 ksi) against 282 MPa (40.9 ksi) for 1037 — about 47% more. Tensile strength is 620 MPa (89.9 ksi) vs 510 MPa (74 ksi).

Which is cheaper, 1037 or 1040?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, 1037 or 1040?

1037. Its weldability rates good (58/100) against fair (45/100) for 1040.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1037 and 1040 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.