FabDigitFabDigit

Refractory Metal R05400 vs Ta-40Nb

Refractory Metal · grade comparison

Refractory Metal R05400 and Ta-40Nb are both refractory metal grades. Ta-40Nb is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 170 MPa (24.7 ksi) for R05400, about 29% more; tensile strength follows at 330 MPa (47.9 ksi) vs 250 MPa (36.3 ksi). In exchange, R05400 is the more ductile: elongation 35% versus 27% for Ta-40Nb, and Ta-40Nb is harder (125 HB vs 90 HB). Ta-40Nb is lighter (12.1 g/cm³ vs 16.6 g/cm³ for R05400) and R05400 is stiffer (186 GPa vs 138 GPa).

R05400Choose it when the part is bent, formed or impact-loaded.

Ta-40NbChoose it when strength drives the design, or when weight is the constraint.

R05400 vs Ta-40Nb: properties

R05400Ta-40Nb

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

186 GPa27 Msi
138 GPa20 Msi

Shear Modulus

69 GPa10 Msi
51 GPa7.4 Msi

Bulk Modulus

200 GPa29 Msi
165 GPa23.9 Msi

Poisson's Ratio

0.35
0.36

Tensile Strength (Ultimate)

250 MPa36.3 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
220 MPa31.9 ksi

Elongation at Break

35%
27%

Reduction in Area

75%
65%

Shear Strength

160 MPa23.2 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
160 MPa23.2 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
—

Hardness, Brinell

90 HB
125 HB

Hardness, Rockwell B

48 HRB
—

Hardness, Vickers

95 HV
130 HV

Physical

Density and transition temperatures.

Density

16.6 g/cm³0.6 lb/in³
12.1 g/cm³0.44 lb/in³

Melting Point (Solidus)

3,017°C5,463 °F
2,650°C4,802 °F

Liquidus Temperature

3,017°C5,463 °F
2,750°C4,982 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

57 W/m·K32.9 BTU/hr·ft·°F
32 W/m·K18.5 BTU/hr·ft·°F

Specific Heat Capacity

140 J/kg·K0.03 BTU/lb·°F
190 J/kg·K0.05 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

6.5 µm/m·K3.6 µin/in·°F
6.8 µm/m·K3.8 µin/in·°F

Latent Heat of Fusion

200 J/g86 BTU/lb
250 J/g107 BTU/lb

Min Service Temperature

-269°C-452 °F
-253°C-423 °F

Same in both: Max Service Temperature (continuous) 300°C572 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

12.8 % IACS
4.3 % IACS

Electrical Resistivity

1.35×10⁻⁷ Ω·m5.31 µΩ·in
4×10⁻⁷ Ω·m15.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.15 V
—

Corrosion Resistance

98 / 100
90 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Weldability

78 / 100
85 / 100

Formability (cold)

95 / 100
85 / 100

Castability

10 / 100
20 / 100

Brazeability / Solderability

55 / 100
50 / 100

Same in both: Machinability 22 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

4,000 MJ/kg1,719,692 BTU/lb
2,800 MJ/kg1,203,784 BTU/lb

Embodied Carbon (primary production)

250 kg CO₂/kg
160 kg CO₂/kg

Embodied Water

900 L/kg108 gal/lb
—

Typical Recycled Content

30%
25%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

15 kN·m/kg
27 kN·m/kg

Specific Stiffness (E / density)

11.2 MN·m/kg
11.4 MN·m/kg

Modulus of Resilience

78 kJ/m³
175 kJ/m³

Thermal Diffusivity

24.5 mm²/s
13.9 mm²/s

Thermal Shock Resistance Index

12
11

Strength versus weight

Yield strength against density for every refractory metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1502003005007001,0001,5005101520Density (g/cm³)Yield strength (MPa) — log scaleTa-40NbR05400

Manufacturing and finishing

CapabilityR05400Ta-40Nb
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

R05400 vs Ta-40Nb — frequently asked

Is Ta-40Nb stronger than R05400?

Yes. Ta-40Nb has a typical yield strength of 220 MPa (31.9 ksi) against 170 MPa (24.7 ksi) for R05400 — about 29% more. Tensile strength is 330 MPa (47.9 ksi) vs 250 MPa (36.3 ksi).

Which is cheaper, R05400 or Ta-40Nb?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, R05400 or Ta-40Nb?

Ta-40Nb. Its weldability rates excellent (85/100) against very good (78/100) for R05400.

Ready to make it?

Upload a CAD file and FabDigit prices the part in R05400 and Ta-40Nb side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.