FabDigitFabDigit

EBA vs EEA

Polymer · grade comparison

EBA and EEA are both polymer grades. EEA is the stronger of the two: tensile strength 12 MPa (1.74 ksi) against 8 MPa (1.16 ksi) for EBA, about 50% more.

EEAChoose it when strength drives the design.

EBA vs EEA: properties

EBAEEA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

8 MPa1.2 ksi
12 MPa1.7 ksi

Flexural Modulus

0.05 GPa0.01 Msi
0.03 GPa0 Msi

Hardness, Shore D

33 Shore D
32 Shore D

Tear Strength

45 kN/m257 lbf/in
60 kN/m343 lbf/in

Yield Strength (0.2% offset)

—
5 MPa0.73 ksi

Same in both: Elastic (Young's) Modulus 0.05 GPa0.01 Msi · Poisson's Ratio 0.46 · Elongation at Break 700% · Hardness, Shore A 88 Shore A

Physical

Density and transition temperatures.

Density

0.93 g/cm³0.03 lb/in³
0.93 g/cm³0.03 lb/in³

Melting Temperature (Tm)

95°C203 °F
98°C208 °F

Glass Transition (Tg)

-45°C-49 °F
-50°C-58 °F

Water Absorption (24 h)

0.03%
0.05%

Refractive Index

1.5
1.49

Light Transmission

85%
—

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.33 W/m·K0.19 BTU/hr·ft·°F
0.3 W/m·K0.17 BTU/hr·ft·°F

Specific Heat Capacity

2,200 J/kg·K0.53 BTU/lb·°F
2,100 J/kg·K0.5 BTU/lb·°F

Max Service Temperature (continuous)

70°C158 °F
65°C149 °F

Min Service Temperature

-60°C-76 °F
-70°C-94 °F

Vicat Softening Point (B50)

55°C131 °F
58°C136 °F

Limiting Oxygen Index

19%
18%

Heat Deflection Temp. @ 0.45 MPa

—
42°C108 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 200 µm/m·K111 µin/in·°F · Max Service Temperature (short-term) 90°C194 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1×10¹² Ω·m3.94×10¹⁹ µΩ·in
1×10¹³ Ω·m3.94×10²⁰ µΩ·in

Dissipation Factor (1 MHz)

0.02
0.03

Volume Resistivity

1×10¹⁴ Ω·cm
1×10¹⁵ Ω·cm

Surface Resistivity

1×10¹⁵ Ω
—

Comparative Tracking Index (CTI)

600 V
—

Same in both: Dielectric Strength 25 kV/mm635 V/mil · Dielectric Constant (1 MHz) 2.9

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
88 / 100

Same in both: UV / Weathering Resistance 35 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

92 / 100
90 / 100

Formability (cold)

90 / 100
95 / 100

Polishability

30 / 100
—

Mold Shrinkage

2%
1.6%

Processing Melt Temperature (typ.)

190°C374 °F
180°C356 °F

Mold Temperature (typ.)

30°C86 °F
25°C77 °F

Same in both: Machinability 15 / 100 · Melt Flow Rate 6 g/10 min

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

82 MJ/kg35,254 BTU/lb
84 MJ/kg36,114 BTU/lb

Embodied Carbon (primary production)

2.6 kg CO₂/kg
2.5 kg CO₂/kg

Embodied Water

110 L/kg13.2 gal/lb
130 L/kg15.6 gal/lb

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

9 kN·m/kg
13 kN·m/kg

Same in both: Specific Stiffness (E / density) 0.1 MN·m/kg · Thermal Diffusivity 0.2 mm²/s · Thermal Shock Resistance Index 0

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scaleEEA

Manufacturing and finishing

CapabilityEBAEEA
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall——
Best machined surface——

EBA vs EEA — frequently asked

Is EEA stronger than EBA?

Yes. EEA has a typical tensile strength of 12 MPa (1.74 ksi) against 8 MPa (1.16 ksi) for EBA — about 50% more.

Which is cheaper, EBA or EEA?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose EBA over EEA?

Pick EEA when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EBA and EEA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.