FabDigitFabDigit

Nickel Alloy IN-100 vs MAR-M247

Nickel Alloy · grade comparison

Nickel Alloy IN-100 and MAR-M247 are both nickel alloy grades. IN-100 is the stronger of the two: tensile strength 1,020 MPa (148 ksi) against 965 MPa (140 ksi) for MAR-M247, about 6% more. IN-100 is the more ductile: elongation 9% versus 7% for MAR-M247, and MAR-M247 is harder (420 HV vs 395 HV). IN-100 is lighter (7.75 g/cm³ vs 8.54 g/cm³ for MAR-M247) and IN-100 conducts heat better (11 W/m·K vs 9.8 W/m·K).

IN-100Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

IN-100 vs MAR-M247: properties

IN-100MAR-M247

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

215 GPa31.2 Msi
205 GPa29.7 Msi

Shear Modulus

83 GPa12 Msi
79 GPa11.5 Msi

Bulk Modulus

175 GPa25.4 Msi
165 GPa23.9 Msi

Poisson's Ratio

0.3
0.29

Tensile Strength (Ultimate)

1,020 MPa148 ksi
965 MPa140 ksi

Yield Strength (0.2% offset)

855 MPa124 ksi
815 MPa118 ksi

Elongation at Break

9%
7%

Reduction in Area

11%
8%

Shear Strength

660 MPa95.7 ksi
630 MPa91.4 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
380 MPa55.1 ksi

Fracture Toughness (K_IC)

65 MPa·√m59.2 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

375 HB
390 HB

Hardness, Rockwell C

40 HRC
42 HRC

Hardness, Vickers

395 HV
420 HV

Compressive Strength

—
900 MPa131 ksi

Physical

Density and transition temperatures.

Density

7.75 g/cm³0.28 lb/in³
8.54 g/cm³0.31 lb/in³

Melting Point (Solidus)

1,265°C2,309 °F
1,315°C2,399 °F

Liquidus Temperature

1,340°C2,444 °F
1,382°C2,520 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

11 W/m·K6.4 BTU/hr·ft·°F
9.8 W/m·K5.7 BTU/hr·ft·°F

Specific Heat Capacity

460 J/kg·K0.11 BTU/lb·°F
420 J/kg·K0.1 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.3 µm/m·K6.8 µin/in·°F
11.8 µm/m·K6.6 µin/in·°F

Max Service Temperature (continuous)

980°C1,796 °F
1,000°C1,832 °F

Min Service Temperature

-196°C-321 °F
-200°C-328 °F

Same in both: Latent Heat of Fusion 290 J/g125 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

1.2 % IACS
1.4 % IACS

Electrical Resistivity

1.4×10⁻⁶ Ω·m55.1 µΩ·in
1.25×10⁻⁶ Ω·m49.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

8%
7%

Weldability

5 / 100
10 / 100

Castability

80 / 100
72 / 100

Brazeability / Solderability

45 / 100
55 / 100

Polishability

60 / 100
70 / 100

Same in both: Machinability 10 / 100 · Formability (cold) 3 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

225 MJ/kg96,733 BTU/lb
230 MJ/kg98,882 BTU/lb

Embodied Carbon (primary production)

16 kg CO₂/kg
14 kg CO₂/kg

Embodied Water

250 L/kg30 gal/lb
1,500 L/kg180 gal/lb

Same in both: Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

132 kN·m/kg
113 kN·m/kg

Specific Stiffness (E / density)

27.7 MN·m/kg
24 MN·m/kg

Modulus of Resilience

1,700 kJ/m³
1,620 kJ/m³

Thermal Diffusivity

3.1 mm²/s
2.7 mm²/s

Same in both: Thermal Shock Resistance Index 4

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleIN-100MAR-M247

Manufacturing and finishing

CapabilityIN-100MAR-M247
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 3 finishes: Gold Plating, Plasma Spray, Silver Plating.

IN-100 vs MAR-M247 — frequently asked

Is IN-100 stronger than MAR-M247?

Yes. IN-100 has a typical tensile strength of 1,020 MPa (148 ksi) against 965 MPa (140 ksi) for MAR-M247 — about 6% more.

Which is cheaper, IN-100 or MAR-M247?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, IN-100 or MAR-M247?

MAR-M247. Its weldability rates not recommended (10/100) against not recommended (5/100) for IN-100.

Ready to make it?

Upload a CAD file and FabDigit prices the part in IN-100 and MAR-M247 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.