FabDigitFabDigit

Copper Alloy C44300-H01 vs C44300-O61

Copper Alloy · C44300 temper comparison

C44300-H01 and C44300-O61 are two conditions of the same copper alloy grade, C44300: H01 (quarter hard) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C44300-H01 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 125 MPa (18.1 ksi) for C44300-O61, about 120% more; tensile strength follows at 400 MPa (58 ksi) vs 340 MPa (49.3 ksi). In exchange, C44300-O61 is the more ductile: elongation 65% versus 40% for C44300-H01, and C44300-H01 is harder (100 HB vs 70 HB).

C44300-H01Choose it when strength drives the design.

C44300-O61Choose it when the part is bent, formed or impact-loaded.

C44300-H01 vs C44300-O61: properties

C44300-H01C44300-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
125 MPa18.1 ksi

Elongation at Break

40%
65%

Compressive Strength

400 MPa58 ksi
340 MPa49.3 ksi

Shear Strength

255 MPa37 ksi
225 MPa32.6 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
125 MPa18.1 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

100 HB
70 HB

Hardness, Vickers

105 HV
75 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.53 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 935°C1,715 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 111 W/m·K64.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 25 % IACS · Electrical Resistivity 6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.29 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

60 / 100
90 / 100

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Castability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC44300

C44300-H01 vs C44300-O61 — frequently asked

Is C44300-H01 stronger than C44300-O61?

Yes. C44300-H01 has a typical yield strength of 275 MPa (39.9 ksi) against 125 MPa (18.1 ksi) for C44300-O61 — about 120% more. Tensile strength is 400 MPa (58 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, H01 or O61?

O61 is the default C44300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C44300-H01 over C44300-O61?

Pick C44300-H01 when strength drives the design. Pick C44300-O61 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C44300-H01 and C44300-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.