FabDigitFabDigit

Copper Alloy C44300-H01 vs C44300-H80

Copper Alloy · C44300 temper comparison

C44300-H01 and C44300-H80 are two conditions of the same copper alloy grade, C44300: H01 (quarter hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C44300-H80 is the stronger of the two: yield strength 350 MPa (50.8 ksi) against 275 MPa (39.9 ksi) for C44300-H01, about 27% more; tensile strength follows at 480 MPa (69.6 ksi) vs 400 MPa (58 ksi). In exchange, C44300-H01 is the more ductile: elongation 40% versus 25% for C44300-H80, and C44300-H80 is harder (130 HB vs 100 HB). C44300-H01 runs hotter in service (200°C vs 175°C continuous).

C44300-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C44300-H80Choose it when strength drives the design.

C44300-H01 vs C44300-H80: properties

C44300-H01C44300-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
350 MPa50.8 ksi

Elongation at Break

40%
25%

Compressive Strength

400 MPa58 ksi
480 MPa69.6 ksi

Shear Strength

255 MPa37 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
150 MPa21.8 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

100 HB
130 HB

Hardness, Vickers

105 HV
138 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.53 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 935°C1,715 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Thermal Conductivity 111 W/m·K64.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
24 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.29 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Weldability

45 / 100
40 / 100

Formability (cold)

60 / 100
35 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC44300

C44300-H01 vs C44300-H80 — frequently asked

Is C44300-H80 stronger than C44300-H01?

Yes. C44300-H80 has a typical yield strength of 350 MPa (50.8 ksi) against 275 MPa (39.9 ksi) for C44300-H01 — about 27% more. Tensile strength is 480 MPa (69.6 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H01 or H80?

O61 is the default C44300 condition in the FabDigit quote flow (neither H01 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C44300-H01 or C44300-H80?

C44300-H80. Its machinability rates fair (35/100) against poor (30/100) for C44300-H01; for welding the order is C44300-H01 first (fair, 45/100) then C44300-H80 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C44300-H01 and C44300-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.