FabDigitFabDigit

Copper Alloy C26200-H02 vs C26200-H04

Copper Alloy · C26200 temper comparison

C26200-H02 and C26200-H04 are two conditions of the same copper alloy grade, C26200: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C26200-H04 is the stronger of the two: yield strength 435 MPa (63.1 ksi) against 379 MPa (55 ksi) for C26200-H02, about 15% more; tensile strength follows at 580 MPa (84.1 ksi) vs 490 MPa (71.1 ksi). In exchange, C26200-H02 is the more ductile: elongation 23% versus 8% for C26200-H04, and C26200-H04 is harder (155 HB vs 125 HB). C26200-H02 runs hotter in service (200°C vs 175°C continuous).

C26200-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C26200-H04Choose it when strength drives the design.

C26200-H02 vs C26200-H04: properties

C26200-H02C26200-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

490 MPa71.1 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

379 MPa55 ksi
435 MPa63.1 ksi

Elongation at Break

23%
8%

Shear Strength

290 MPa42.1 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
160 MPa23.2 ksi

Hardness, Brinell

125 HB
155 HB

Hardness, Rockwell B

70 HRB
82 HRB

Hardness, Vickers

130 HV
165 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 915°C1,679 °F · Liquidus Temperature 955°C1,751 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Thermal Conductivity 120 W/m·K69.3 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.9 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 28 % IACS · Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 57 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
35 / 100

Formability (cold)

60 / 100
38 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.3 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC26200

C26200-H02 vs C26200-H04 — frequently asked

Is C26200-H04 stronger than C26200-H02?

Yes. C26200-H04 has a typical yield strength of 435 MPa (63.1 ksi) against 379 MPa (55 ksi) for C26200-H02 — about 15% more. Tensile strength is 580 MPa (84.1 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C26200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C26200-H02 over C26200-H04?

Pick C26200-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C26200-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C26200-H02 and C26200-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.