FabDigitFabDigit

Copper Alloy C26200-H02 vs C26200-H08

Copper Alloy · C26200 temper comparison

C26200-H02 and C26200-H08 are two conditions of the same copper alloy grade, C26200: H02 (half hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C26200-H08 is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 379 MPa (55 ksi) for C26200-H02, about 24% more; tensile strength follows at 690 MPa (100 ksi) vs 490 MPa (71.1 ksi). In exchange, C26200-H02 is the more ductile: elongation 23% versus 4% for C26200-H08, and C26200-H08 is harder (185 HB vs 125 HB). C26200-H02 runs hotter in service (200°C vs 150°C continuous).

C26200-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C26200-H08Choose it when strength drives the design.

C26200-H02 vs C26200-H08: properties

C26200-H02C26200-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

490 MPa71.1 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

379 MPa55 ksi
470 MPa68.2 ksi

Elongation at Break

23%
4%

Shear Strength

290 MPa42.1 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
170 MPa24.7 ksi

Hardness, Brinell

125 HB
185 HB

Hardness, Rockwell B

70 HRB
91 HRB

Hardness, Vickers

130 HV
195 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 915°C1,679 °F · Liquidus Temperature 955°C1,751 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Thermal Conductivity 120 W/m·K69.3 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.9 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 28 % IACS · Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 57 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
37 / 100

Formability (cold)

60 / 100
22 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.3 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC26200

C26200-H02 vs C26200-H08 — frequently asked

Is C26200-H08 stronger than C26200-H02?

Yes. C26200-H08 has a typical yield strength of 470 MPa (68.2 ksi) against 379 MPa (55 ksi) for C26200-H02 — about 24% more. Tensile strength is 690 MPa (100 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, H02 or H08?

H02 is the default C26200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C26200-H02 or C26200-H08?

C26200-H08. Its machinability rates fair (37/100) against poor (32/100) for C26200-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C26200-H02 and C26200-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.