FabDigitFabDigit

Copper Alloy C26200-H04 vs C26200-H10

Copper Alloy · C26200 temper comparison

C26200-H04 and C26200-H10 are two conditions of the same copper alloy grade, C26200: H04 (full hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C26200-H10 is the stronger of the two: yield strength 485 MPa (70.3 ksi) against 435 MPa (63.1 ksi) for C26200-H04, about 11% more; tensile strength follows at 725 MPa (105 ksi) vs 580 MPa (84.1 ksi). In exchange, C26200-H04 is the more ductile: elongation 8% versus 3% for C26200-H10, and C26200-H10 is harder (195 HB vs 155 HB). C26200-H04 runs hotter in service (175°C vs 150°C continuous).

C26200-H04Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C26200-H10Choose it when strength drives the design.

C26200-H04 vs C26200-H10: properties

C26200-H04C26200-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

580 MPa84.1 ksi
725 MPa105 ksi

Yield Strength (0.2% offset)

435 MPa63.1 ksi
485 MPa70.3 ksi

Elongation at Break

8%
3%

Shear Strength

315 MPa45.7 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
175 MPa25.4 ksi

Hardness, Brinell

155 HB
195 HB

Hardness, Rockwell B

82 HRB
93 HRB

Hardness, Vickers

165 HV
205 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 915°C1,679 °F · Liquidus Temperature 955°C1,751 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 120 W/m·K69.3 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.9 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 28 % IACS · Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 57 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Formability (cold)

38 / 100
18 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.3 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC26200

C26200-H04 vs C26200-H10 — frequently asked

Is C26200-H10 stronger than C26200-H04?

Yes. C26200-H10 has a typical yield strength of 485 MPa (70.3 ksi) against 435 MPa (63.1 ksi) for C26200-H04 — about 11% more. Tensile strength is 725 MPa (105 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, H04 or H10?

H02 is the default C26200 condition in the FabDigit quote flow (neither H04 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C26200-H04 over C26200-H10?

Pick C26200-H04 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C26200-H10 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C26200-H04 and C26200-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.