FabDigitFabDigit

Aluminum EN AC-43200-T5 vs EN AC-43200-T6

Aluminum · EN AC-43200 temper comparison

EN AC-43200-T5 and EN AC-43200-T6 are two conditions of the same aluminum grade, EN AC-43200: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43200-T6 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 130 MPa (18.9 ksi) for EN AC-43200-T5, about 69% more; tensile strength follows at 260 MPa (37.7 ksi) vs 200 MPa (29 ksi). EN AC-43200-T6 is harder — 90 HB against 70 HB for EN AC-43200-T5 — which matters for wear surfaces and threads. On the shop floor, EN AC-43200-T6 welds better (good vs fair).

EN AC-43200-T6Choose it when strength drives the design, or when surface hardness matters.

EN AC-43200-T5 vs EN AC-43200-T6: properties

EN AC-43200-T5EN AC-43200-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
220 MPa31.9 ksi

Compressive Strength

140 MPa20.3 ksi
260 MPa37.7 ksi

Shear Strength

125 MPa18.1 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

80 MPa11.6 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

16 MPa·√m14.6 ksi·√in
17 MPa·√m15.5 ksi·√in

Hardness, Brinell

70 HB
90 HB

Hardness, Vickers

76 HV
95 HV

Same in both: Elastic (Young's) Modulus 73 GPa10.6 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Elongation at Break 1.5% · Charpy V-Notch Impact (RT) 3 J2.2 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

160°C320 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
39 % IACS

Electrical Resistivity

4.5×10⁻⁸ Ω·m1.77 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.83 V
-0.82 V

Corrosion Resistance

44 / 100
52 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

42 / 100
55 / 100

Formability (cold)

8 / 100
10 / 100

Brazeability / Solderability

35 / 100
30 / 100

Polishability

45 / 100
50 / 100

Same in both: Castability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

150 MJ/kg64,488 BTU/lb
155 MJ/kg66,638 BTU/lb

Embodied Carbon (primary production)

9.5 kg CO₂/kg
10 kg CO₂/kg

Same in both: Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43200

EN AC-43200-T5 vs EN AC-43200-T6 — frequently asked

Is EN AC-43200-T6 stronger than EN AC-43200-T5?

Yes. EN AC-43200-T6 has a typical yield strength of 220 MPa (31.9 ksi) against 130 MPa (18.9 ksi) for EN AC-43200-T5 — about 69% more. Tensile strength is 260 MPa (37.7 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, T5 or T6?

F is the default EN AC-43200 condition in the FabDigit quote flow (neither T5 nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-43200-T5 or EN AC-43200-T6?

EN AC-43200-T6. Its weldability rates good (55/100) against fair (42/100) for EN AC-43200-T5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43200-T5 and EN AC-43200-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.