Aluminum EN AC-43200-F vs EN AC-43200-T5

Aluminum · EN AC-43200 temper comparison

EN AC-43200-F and EN AC-43200-T5 are two conditions of the same aluminum grade, EN AC-43200: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43200-T5 is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 100 MPa (14.5 ksi) for EN AC-43200-F, about 30% more; tensile strength follows at 200 MPa (29 ksi) vs 190 MPa (27.6 ksi). In exchange, EN AC-43200-F is the more ductile: elongation 2% versus 1.5% for EN AC-43200-T5, and EN AC-43200-T5 is harder (70 HB vs 60 HB). On the shop floor, EN AC-43200-T5 machines more easily (good vs fair) and EN AC-43200-F welds better (good vs fair).

EN AC-43200-FChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

EN AC-43200-T5Choose it when strength drives the design, or when the part is machined in volume.

EN AC-43200-F vs EN AC-43200-T5: properties

EN AC-43200-FEN AC-43200-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

72 GPa10.4 Msi
73 GPa10.6 Msi

Tensile Strength (Ultimate)

190 MPa27.6 ksi
200 MPa29 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
130 MPa18.9 ksi

Elongation at Break

2%
1.5%

Compressive Strength

190 MPa27.6 ksi
140 MPa20.3 ksi

Shear Strength

140 MPa20.3 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
80 MPa11.6 ksi

Fracture Toughness (K_IC)

18 MPa·√m16.4 ksi·√in
16 MPa·√m14.6 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

60 HB
70 HB

Hardness, Vickers

60 HV
76 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
160°C320 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

37 % IACS
38 % IACS

Electrical Resistivity

4.7×10⁻⁸ Ω·m1.85 µΩ·in
4.5×10⁻⁸ Ω·m1.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
44 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
65%

Weldability

65 / 100
42 / 100

Formability (cold)

15 / 100
8 / 100

Same in both: Castability 90 / 100 · Brazeability / Solderability 35 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43200

EN AC-43200-F vs EN AC-43200-T5 — frequently asked

Is EN AC-43200-T5 stronger than EN AC-43200-F?

Yes. EN AC-43200-T5 has a typical yield strength of 130 MPa (18.9 ksi) against 100 MPa (14.5 ksi) for EN AC-43200-F — about 30% more. Tensile strength is 200 MPa (29 ksi) vs 190 MPa (27.6 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default EN AC-43200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-43200-F or EN AC-43200-T5?

EN AC-43200-T5. Its machinability rates good (60/100) against fair (50/100) for EN AC-43200-F; for welding the order is EN AC-43200-F first (good, 65/100) then EN AC-43200-T5 (fair, 42/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43200-F and EN AC-43200-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.