EN AC-43200-F and EN AC-43200-T6 are two conditions of the same aluminum grade, EN AC-43200: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43200-T6 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 100 MPa (14.5 ksi) for EN AC-43200-F, about 120% more; tensile strength follows at 260 MPa (37.7 ksi) vs 190 MPa (27.6 ksi). In exchange, EN AC-43200-F is the more ductile: elongation 2% versus 1.5% for EN AC-43200-T6, and EN AC-43200-T6 is harder (90 HB vs 60 HB). On the shop floor, EN AC-43200-F welds better (65 vs 55 out of 100).

EN AC-43200-FChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

EN AC-43200-T6Choose it when strength drives the design.

EN AC-43200-F vs EN AC-43200-T6: properties

EN AC-43200-FEN AC-43200-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

72 GPa10.4 Msi
73 GPa10.6 Msi

Tensile Strength (Ultimate)

190 MPa27.6 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
220 MPa31.9 ksi

Elongation at Break

2%
1.5%

Compressive Strength

190 MPa27.6 ksi
260 MPa37.7 ksi

Shear Strength

140 MPa20.3 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

18 MPa·√m16.4 ksi·√in
17 MPa·√m15.5 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

60 HB
90 HB

Hardness, Vickers

60 HV
95 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

37 % IACS
39 % IACS

Electrical Resistivity

4.7×10⁻⁸ Ω·m1.85 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.83 V
-0.82 V

Corrosion Resistance

55 / 100
52 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
55%

Weldability

65 / 100
55 / 100

Formability (cold)

15 / 100
10 / 100

Brazeability / Solderability

35 / 100
30 / 100

Polishability

45 / 100
50 / 100

Same in both: Castability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

150 MJ/kg64,488 BTU/lb
155 MJ/kg66,638 BTU/lb

Embodied Carbon (primary production)

9.5 kg CO₂/kg
10 kg CO₂/kg

Same in both: Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43200

EN AC-43200-F vs EN AC-43200-T6 — frequently asked

Is EN AC-43200-T6 stronger than EN AC-43200-F?

Yes. EN AC-43200-T6 has a typical yield strength of 220 MPa (31.9 ksi) against 100 MPa (14.5 ksi) for EN AC-43200-F — about 120% more. Tensile strength is 260 MPa (37.7 ksi) vs 190 MPa (27.6 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default EN AC-43200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-43200-F or EN AC-43200-T6?

EN AC-43200-T6. Its machinability rates good (58/100) against fair (50/100) for EN AC-43200-F; for welding the order is EN AC-43200-F first (good, 65/100) then EN AC-43200-T6 (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43200-F and EN AC-43200-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.