FabDigitFabDigit

Aluminum EN AC-43200-T5 vs EN AC-43200-T64

Aluminum · EN AC-43200 temper comparison

EN AC-43200-T5 and EN AC-43200-T64 are two conditions of the same aluminum grade, EN AC-43200: T5 (cooled from hot working and artificially aged) versus T64 (solution heat treated and under-aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43200-T64 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 130 MPa (18.9 ksi) for EN AC-43200-T5, about 15% more. EN AC-43200-T64 is the more ductile: elongation 3% versus 1.5% for EN AC-43200-T5, and EN AC-43200-T64 is harder (75 HB vs 70 HB). EN AC-43200-T5 conducts heat better (155 W/m·K vs 130 W/m·K).

EN AC-43200-T64Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-43200-T5 vs EN AC-43200-T64: properties

EN AC-43200-T5EN AC-43200-T64

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
150 MPa21.8 ksi

Elongation at Break

1.5%
3%

Compressive Strength

140 MPa20.3 ksi
155 MPa22.5 ksi

Shear Strength

125 MPa18.1 ksi
135 MPa19.6 ksi

Fatigue Strength (Endurance Limit)

80 MPa11.6 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

16 MPa·√m14.6 ksi·√in
18 MPa·√m16.4 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

70 HB
75 HB

Hardness, Vickers

76 HV
82 HV

Same in both: Elastic (Young's) Modulus 73 GPa10.6 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Max Service Temperature (continuous) 160°C320 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
31 % IACS

Electrical Resistivity

4.5×10⁻⁸ Ω·m1.77 µΩ·in
5.6×10⁻⁸ Ω·m2.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

44 / 100
43 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
62 / 100

Weldability

42 / 100
40 / 100

Formability (cold)

8 / 100
12 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 65% · Castability 90 / 100 · Brazeability / Solderability 35 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43200

EN AC-43200-T5 vs EN AC-43200-T64 — frequently asked

Is EN AC-43200-T64 stronger than EN AC-43200-T5?

Yes. EN AC-43200-T64 has a typical yield strength of 150 MPa (21.8 ksi) against 130 MPa (18.9 ksi) for EN AC-43200-T5 — about 15% more. Tensile strength is 210 MPa (30.5 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, T5 or T64?

F is the default EN AC-43200 condition in the FabDigit quote flow (neither T5 nor T64). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-43200-T5 over EN AC-43200-T64?

Pick EN AC-43200-T64 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43200-T5 and EN AC-43200-T64 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.