FabDigitFabDigit

Aluminum B390.0-F vs B390.0-T5

Aluminum · B390.0 temper comparison

B390.0-F and B390.0-T5 are two conditions of the same aluminum grade, B390.0: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. B390.0-T5 is the stronger of the two: yield strength 265 MPa (38.4 ksi) against 240 MPa (34.8 ksi) for B390.0-F, about 10% more; tensile strength follows at 300 MPa (43.5 ksi) vs 280 MPa (40.6 ksi). B390.0-T5 is harder — 140 HB against 120 HB for B390.0-F — which matters for wear surfaces and threads.

B390.0-T5Choose it when strength drives the design, or when surface hardness matters.

B390.0-F vs B390.0-T5: properties

B390.0-FB390.0-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

280 MPa40.6 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
265 MPa38.4 ksi

Shear Strength

190 MPa27.6 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
145 MPa21 ksi

Fracture Toughness (K_IC)

14 MPa·√m12.7 ksi·√in
13 MPa·√m11.8 ksi·√in

Hardness, Brinell

120 HB
140 HB

Same in both: Elastic (Young's) Modulus 81 GPa11.7 Msi · Shear Modulus 30.5 GPa4.4 Msi · Bulk Modulus 79 GPa11.5 Msi · Poisson's Ratio 0.33 · Elongation at Break 1% · Charpy V-Notch Impact (RT) 2 J1.5 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 507°C945 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

134 W/m·K77.4 BTU/hr·ft·°F
137 W/m·K79.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 860 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 470 J/g202 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
28 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.76 V · Corrosion Resistance 35 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Formability (cold)

5 / 100
4 / 100

Same in both: Weldability 20 / 100 · Castability 80 / 100 · Brazeability / Solderability 20 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleB390.0

B390.0-F vs B390.0-T5 — frequently asked

Is B390.0-T5 stronger than B390.0-F?

Yes. B390.0-T5 has a typical yield strength of 265 MPa (38.4 ksi) against 240 MPa (34.8 ksi) for B390.0-F — about 10% more. Tensile strength is 300 MPa (43.5 ksi) vs 280 MPa (40.6 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default B390.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose B390.0-F over B390.0-T5?

Pick B390.0-T5 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in B390.0-F and B390.0-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.