A2024-RAM2-SR and A2024-RAM2-T4 are two conditions of the same aluminum grade, A2024-RAM2: SR (stress relieved) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. A2024-RAM2-T4 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 200 MPa (29 ksi) for A2024-RAM2-SR, about 65% more; tensile strength follows at 470 MPa (68.2 ksi) vs 300 MPa (43.5 ksi). A2024-RAM2-T4 is harder — 120 HB against 85 HB for A2024-RAM2-SR — which matters for wear surfaces and threads. A2024-RAM2-SR runs hotter in service (200°C vs 120°C continuous) and A2024-RAM2-SR conducts heat better (145 W/m·K vs 115 W/m·K). On the shop floor, A2024-RAM2-SR forms better (fair vs poor).

A2024-RAM2-SRChoose it when the part sees heat.

A2024-RAM2-T4Choose it when strength drives the design, or when surface hardness matters.

A2024-RAM2-SR vs A2024-RAM2-T4: properties

A2024-RAM2-SRA2024-RAM2-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

76 GPa11 Msi
78 GPa11.3 Msi

Tensile Strength (Ultimate)

300 MPa43.5 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
330 MPa47.9 ksi

Elongation at Break

12%
11%

Compressive Strength

210 MPa30.5 ksi
440 MPa63.8 ksi

Shear Strength

190 MPa27.6 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
125 MPa18.1 ksi

Fracture Toughness (K_IC)

28 MPa·√m25.5 ksi·√in
26 MPa·√m23.7 ksi·√in

Hardness, Brinell

85 HB
120 HB

Hardness, Rockwell B

45 HRB
82 HRB

Hardness, Vickers

90 HV
128 HV

Same in both: Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
115 W/m·K66.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
120°C248 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
30 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
33 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

110%
130%

Weldability

30 / 100
25 / 100

Formability (cold)

35 / 100
15 / 100

Same in both: Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 260 MJ/kg111,780 BTU/lb · Embodied Carbon (primary production) 15 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA2024-RAM2

A2024-RAM2-SR vs A2024-RAM2-T4 — frequently asked

Is A2024-RAM2-T4 stronger than A2024-RAM2-SR?

Yes. A2024-RAM2-T4 has a typical yield strength of 330 MPa (47.9 ksi) against 200 MPa (29 ksi) for A2024-RAM2-SR — about 65% more. Tensile strength is 470 MPa (68.2 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, SR or T4?

T6 is the default A2024-RAM2 condition in the FabDigit quote flow (neither SR nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A2024-RAM2-SR or A2024-RAM2-T4?

A2024-RAM2-T4. Its machinability rates good (55/100) against fair (50/100) for A2024-RAM2-SR; for welding the order is A2024-RAM2-SR first (poor, 30/100) then A2024-RAM2-T4 (poor, 25/100).