Aluminum A2024-RAM2-SR vs A2024-RAM2-T4
Aluminum · A2024-RAM2 temper comparison
A2024-RAM2-SR and A2024-RAM2-T4 are two conditions of the same aluminum grade, A2024-RAM2: SR (stress relieved) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. A2024-RAM2-T4 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 200 MPa (29 ksi) for A2024-RAM2-SR, about 65% more; tensile strength follows at 470 MPa (68.2 ksi) vs 300 MPa (43.5 ksi). A2024-RAM2-T4 is harder — 120 HB against 85 HB for A2024-RAM2-SR — which matters for wear surfaces and threads. A2024-RAM2-SR runs hotter in service (200°C vs 120°C continuous) and A2024-RAM2-SR conducts heat better (145 W/m·K vs 115 W/m·K). On the shop floor, A2024-RAM2-SR forms better (fair vs poor).
A2024-RAM2-SRChoose it when the part sees heat.
A2024-RAM2-T4Choose it when strength drives the design, or when surface hardness matters.
A2024-RAM2-SR vs A2024-RAM2-T4: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33
Physical
Density and transition temperatures.
Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Brazeability / Solderability 15 / 100 · Polishability 55 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 260 MJ/kg111,780 BTU/lb · Embodied Carbon (primary production) 15 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%
Strength versus weight
Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
A2024-RAM2-SR vs A2024-RAM2-T4 — frequently asked
Is A2024-RAM2-T4 stronger than A2024-RAM2-SR?
Yes. A2024-RAM2-T4 has a typical yield strength of 330 MPa (47.9 ksi) against 200 MPa (29 ksi) for A2024-RAM2-SR — about 65% more. Tensile strength is 470 MPa (68.2 ksi) vs 300 MPa (43.5 ksi).
Which condition does FabDigit quote by default, SR or T4?
T6 is the default A2024-RAM2 condition in the FabDigit quote flow (neither SR nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, A2024-RAM2-SR or A2024-RAM2-T4?
A2024-RAM2-T4. Its machinability rates good (55/100) against fair (50/100) for A2024-RAM2-SR; for welding the order is A2024-RAM2-SR first (poor, 30/100) then A2024-RAM2-T4 (poor, 25/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in A2024-RAM2-SR and A2024-RAM2-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.