FabDigitFabDigit

Aluminum 6005 vs 6182

Aluminum · grade comparison

Aluminum 6005 and 6182 are both aluminum grades. 6182 is the stronger of the two: yield strength 290 MPa (42.1 ksi) against 245 MPa (35.5 ksi) for 6005, about 18% more; tensile strength follows at 330 MPa (47.9 ksi) vs 270 MPa (39.2 ksi). 6182 is harder — 98 HB against 85 HB for 6005 — which matters for wear surfaces and threads. 6005 conducts electricity better (49 % IACS vs 42 % IACS).

6182Choose it when strength drives the design, or when surface hardness matters.

6005 vs 6182: properties

60056182

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

69 GPa10 Msi
69.5 GPa10.1 Msi

Tensile Strength (Ultimate)

270 MPa39.2 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

245 MPa35.5 ksi
290 MPa42.1 ksi

Elongation at Break

11%
10%

Shear Strength

172 MPa24.9 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
95 MPa13.8 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
29 MPa·√m26.4 ksi·√in

Hardness, Brinell

85 HB
98 HB

Hardness, Vickers

90 HV
105 HV

Charpy V-Notch Impact (RT)

—
18 J13.3 ft·lbf

Hardness, Rockwell B

—
60 HRB

Same in both: Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Melting Point (Solidus)

607°C1,125 °F
585°C1,085 °F

Liquidus Temperature

654°C1,209 °F
650°C1,202 °F

Same in both: Density 2.7 g/cm³0.1 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

188 W/m·K109 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Specific Heat Capacity

897 J/kg·K0.21 BTU/lb·°F
900 J/kg·K0.21 BTU/lb·°F

Latent Heat of Fusion

397 J/g171 BTU/lb
393 J/g169 BTU/lb

Same in both: Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

49 % IACS
42 % IACS

Electrical Resistivity

3.52×10⁻⁸ Ω·m1.39 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.83 V
-0.74 V

Corrosion Resistance

70 / 100
65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
150%

Weldability

80 / 100
72 / 100

Formability (cold)

40 / 100
45 / 100

Brazeability / Solderability

50 / 100
45 / 100

Polishability

65 / 100
70 / 100

Castability

—
35 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

1,200 L/kg144 gal/lb
1,150 L/kg138 gal/lb

Typical Recycled Content

30%
35%

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

100 kN·m/kg
122 kN·m/kg

Specific Stiffness (E / density)

25.6 MN·m/kg
25.7 MN·m/kg

Modulus of Resilience

435 kJ/m³
605 kJ/m³

Thermal Diffusivity

77.6 mm²/s
70 mm²/s

Thermal Shock Resistance Index

31
34

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale60056182

Manufacturing and finishing

Capability60056182
CNC machiningYes—
Sheet metalYes—
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall0.5 mm—
Best machined surfaceRa 0.8 µm—
Anodizing Type IIYes—
CerakoteYes—
Chem Film (Alodine)Yes—
DLCYes—
E-CoatingYes—
ElectropolishingYes—
Hard Anodize Type III w/ PTFEYes—
Hard Anodizing Type IIIYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—
Powder CoatingYes—

They share 4 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Silver Plating.

6005 vs 6182 — frequently asked

Is 6182 stronger than 6005?

Yes. 6182 has a typical yield strength of 290 MPa (42.1 ksi) against 245 MPa (35.5 ksi) for 6005 — about 18% more. Tensile strength is 330 MPa (47.9 ksi) vs 270 MPa (39.2 ksi).

Which is cheaper, 6005 or 6182?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, 6005 or 6182?

6005. Its weldability rates very good (80/100) against very good (72/100) for 6182.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6005 and 6182 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.