Aluminum 6005 and 6082 are both aluminum grades. 6082 is the stronger of the two: yield strength 265 MPa (38.4 ksi) against 245 MPa (35.5 ksi) for 6005, about 8% more; tensile strength follows at 310 MPa (45 ksi) vs 270 MPa (39.2 ksi). 6082 is harder — 95 HB against 85 HB for 6005 — which matters for wear surfaces and threads. 6005 conducts electricity better (49 % IACS vs 41 % IACS).

6082Choose it when strength drives the design, or when surface hardness matters.

6005 vs 6082: properties

60056082

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

69 GPa10 Msi
70 GPa10.2 Msi

Tensile Strength (Ultimate)

270 MPa39.2 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

245 MPa35.5 ksi
265 MPa38.4 ksi

Elongation at Break

11%
10%

Shear Strength

172 MPa24.9 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
95 MPa13.8 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
29 MPa·√m26.4 ksi·√in

Hardness, Brinell

85 HB
95 HB

Hardness, Vickers

90 HV
100 HV

Hardness, Rockwell B

—
60 HRB

Same in both: Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Melting Point (Solidus)

607°C1,125 °F
555°C1,031 °F

Liquidus Temperature

654°C1,209 °F
650°C1,202 °F

Same in both: Density 2.7 g/cm³0.1 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

188 W/m·K109 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Specific Heat Capacity

897 J/kg·K0.21 BTU/lb·°F
900 J/kg·K0.21 BTU/lb·°F

Latent Heat of Fusion

397 J/g171 BTU/lb
390 J/g168 BTU/lb

Same in both: Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

49 % IACS
41 % IACS

Electrical Resistivity

3.52×10⁻⁸ Ω·m1.39 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
—

Weldability

80 / 100
75 / 100

Brazeability / Solderability

50 / 100
35 / 100

Polishability

65 / 100
55 / 100

Same in both: Formability (cold) 40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

1,200 L/kg144 gal/lb
1,150 L/kg138 gal/lb

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

100 kN·m/kg
115 kN·m/kg

Specific Stiffness (E / density)

25.6 MN·m/kg
25.9 MN·m/kg

Modulus of Resilience

435 kJ/m³
502 kJ/m³

Thermal Diffusivity

77.6 mm²/s
70 mm²/s

Thermal Shock Resistance Index

31
32

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale60056082

Manufacturing and finishing

Capability60056082
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall0.5 mm0.5 mm
Best machined surfaceRa 0.8 µmRa 0.8 µm

Both are offered for CNC machining and Sheet metal. Both take the same 16 finishes: Anodizing Type II, Cerakote, Chem Film (Alodine), DLC, E-Coating, Electroless Nickel (EN), Electropolishing, Epoxy Coating, Gold Plating, Hard Anodize Type III w/ PTFE, Hard Anodizing Type III, Nickel Plating and 4 more.

6005 vs 6082 — frequently asked

Is 6082 stronger than 6005?

Yes. 6082 has a typical yield strength of 265 MPa (38.4 ksi) against 245 MPa (35.5 ksi) for 6005 — about 8% more. Tensile strength is 310 MPa (45 ksi) vs 270 MPa (39.2 ksi).

Which is cheaper, 6005 or 6082?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 6005 or 6082?

6082, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 6005; for welding the order is 6005 first (very good, 80/100) then 6082 (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6005 and 6082 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.