1230A-H26 and 1230A-O are two conditions of the same aluminum grade, 1230A: H26 (strain hardened and partially annealed, three-quarter hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1230A-H26 is the stronger of the two: yield strength 100 MPa (14.5 ksi) against 30 MPa (4.35 ksi) for 1230A-O, about 3.3 times as much; tensile strength follows at 125 MPa (18.1 ksi) vs 85 MPa (12.3 ksi). In exchange, 1230A-O is the more ductile: elongation 38% versus 7% for 1230A-H26, and 1230A-H26 is harder (36 HB vs 23 HB). 1230A-O runs hotter in service (150°C vs 120°C continuous). On the shop floor, 1230A-H26 machines more easily (fair vs poor).

1230A-H26Choose it when strength drives the design, or when the part is machined in volume.

1230A-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1230A-H26 vs 1230A-O: properties

1230A-H261230A-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
85 MPa12.3 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
30 MPa4.4 ksi

Elongation at Break

7%
38%

Shear Strength

76 MPa11 ksi
55 MPa8 ksi

Fatigue Strength (Endurance Limit)

45 MPa6.5 ksi
34 MPa4.9 ksi

Hardness, Brinell

36 HB
23 HB

Hardness, Vickers

39 HV
25 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

226 W/m·K131 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
60.5 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
2.85×10⁻⁸ Ω·m1.12 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
74 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
30%

Weldability

92 / 100
93 / 100

Formability (cold)

70 / 100
99 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1230A

1230A-H26 vs 1230A-O — frequently asked

Is 1230A-H26 stronger than 1230A-O?

Yes. 1230A-H26 has a typical yield strength of 100 MPa (14.5 ksi) against 30 MPa (4.35 ksi) for 1230A-O — about 3.3 times as much. Tensile strength is 125 MPa (18.1 ksi) vs 85 MPa (12.3 ksi).

Which condition does FabDigit quote by default, H26 or O?

O is the default 1230A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1230A-H26 or 1230A-O?

1230A-H26. Its machinability rates fair (35/100) against poor (25/100) for 1230A-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1230A-H26 and 1230A-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.