Aluminum 1230A-H112 vs 1230A-H26
Aluminum · 1230A temper comparison
1230A-H112 and 1230A-H26 are two conditions of the same aluminum grade, 1230A: H112 (strain hardened from hot working only) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 1230A-H26 is the stronger of the two: yield strength 100 MPa (14.5 ksi) against 35 MPa (5.08 ksi) for 1230A-H112, about 186% more; tensile strength follows at 125 MPa (18.1 ksi) vs 85 MPa (12.3 ksi). In exchange, 1230A-H112 is the more ductile: elongation 25% versus 7% for 1230A-H26, and 1230A-H26 is harder (36 HB vs 24 HB). 1230A-H112 runs hotter in service (150°C vs 120°C continuous).
1230A-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.
1230A-H26Choose it when strength drives the design.
1230A-H112 vs 1230A-H26: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33
Physical
Density and transition temperatures.
Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%
Strength versus weight
Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
1230A-H112 vs 1230A-H26 — frequently asked
Is 1230A-H26 stronger than 1230A-H112?
Yes. 1230A-H26 has a typical yield strength of 100 MPa (14.5 ksi) against 35 MPa (5.08 ksi) for 1230A-H112 — about 186% more. Tensile strength is 125 MPa (18.1 ksi) vs 85 MPa (12.3 ksi).
Which condition does FabDigit quote by default, H112 or H26?
O is the default 1230A condition in the FabDigit quote flow (neither H112 nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, 1230A-H112 or 1230A-H26?
1230A-H26. Its machinability rates fair (35/100) against poor (27/100) for 1230A-H112.
Ready to make it?
Upload a CAD file and FabDigit prices the part in 1230A-H112 and 1230A-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.