FabDigitFabDigit

Aluminum 1230A-H22 vs 1230A-H26

Aluminum · 1230A temper comparison

1230A-H22 and 1230A-H26 are two conditions of the same aluminum grade, 1230A: H22 (strain hardened and partially annealed, quarter hard) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 1230A-H26 is the stronger of the two: yield strength 100 MPa (14.5 ksi) against 65 MPa (9.43 ksi) for 1230A-H22, about 54% more; tensile strength follows at 125 MPa (18.1 ksi) vs 95 MPa (13.8 ksi). In exchange, 1230A-H22 is the more ductile: elongation 14% versus 7% for 1230A-H26, and 1230A-H26 is harder (36 HB vs 27 HB).

1230A-H22Choose it when the part is bent, formed or impact-loaded.

1230A-H26Choose it when strength drives the design.

1230A-H22 vs 1230A-H26: properties

1230A-H221230A-H26

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

95 MPa13.8 ksi
125 MPa18.1 ksi

Yield Strength (0.2% offset)

65 MPa9.4 ksi
100 MPa14.5 ksi

Elongation at Break

14%
7%

Shear Strength

62 MPa9 ksi
76 MPa11 ksi

Fatigue Strength (Endurance Limit)

38 MPa5.5 ksi
45 MPa6.5 ksi

Hardness, Brinell

27 HB
36 HB

Hardness, Vickers

29 HV
39 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

229 W/m·K132 BTU/hr·ft·°F
226 W/m·K131 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

60 % IACS
59 % IACS

Electrical Resistivity

2.87×10⁻⁸ Ω·m1.13 µΩ·in
2.92×10⁻⁸ Ω·m1.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
38%

Formability (cold)

92 / 100
70 / 100

Same in both: Weldability 92 / 100 · Castability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1230A

1230A-H22 vs 1230A-H26 — frequently asked

Is 1230A-H26 stronger than 1230A-H22?

Yes. 1230A-H26 has a typical yield strength of 100 MPa (14.5 ksi) against 65 MPa (9.43 ksi) for 1230A-H22 — about 54% more. Tensile strength is 125 MPa (18.1 ksi) vs 95 MPa (13.8 ksi).

Which condition does FabDigit quote by default, H22 or H26?

O is the default 1230A condition in the FabDigit quote flow (neither H22 nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1230A-H22 or 1230A-H26?

1230A-H26. Its machinability rates fair (35/100) against poor (30/100) for 1230A-H22.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1230A-H22 and 1230A-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.