1230A-H112 and 1230A-H24 are two conditions of the same aluminum grade, 1230A: H112 (strain hardened from hot working only) versus H24 (strain hardened and partially annealed, half hard). The chemistry is identical, so every difference below comes from the condition. 1230A-H24 is the stronger of the two: yield strength 85 MPa (12.3 ksi) against 35 MPa (5.08 ksi) for 1230A-H112, about 143% more; tensile strength follows at 110 MPa (16 ksi) vs 85 MPa (12.3 ksi). In exchange, 1230A-H112 is the more ductile: elongation 25% versus 11% for 1230A-H24, and 1230A-H24 is harder (31 HB vs 24 HB). 1230A-H112 runs hotter in service (150°C vs 120°C continuous).

1230A-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1230A-H24Choose it when strength drives the design.

1230A-H112 vs 1230A-H24: properties

1230A-H1121230A-H24

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

85 MPa12.3 ksi
110 MPa16 ksi

Yield Strength (0.2% offset)

35 MPa5.1 ksi
85 MPa12.3 ksi

Elongation at Break

25%
11%

Shear Strength

57 MPa8.3 ksi
70 MPa10.2 ksi

Fatigue Strength (Endurance Limit)

35 MPa5.1 ksi
41 MPa5.9 ksi

Hardness, Brinell

24 HB
31 HB

Hardness, Vickers

26 HV
34 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

230 W/m·K133 BTU/hr·ft·°F
227 W/m·K131 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

60 % IACS
59.5 % IACS

Electrical Resistivity

2.87×10⁻⁸ Ω·m1.13 µΩ·in
2.9×10⁻⁸ Ω·m1.14 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

27 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Weldability

93 / 100
92 / 100

Formability (cold)

95 / 100
85 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1230A

1230A-H112 vs 1230A-H24 — frequently asked

Is 1230A-H24 stronger than 1230A-H112?

Yes. 1230A-H24 has a typical yield strength of 85 MPa (12.3 ksi) against 35 MPa (5.08 ksi) for 1230A-H112 — about 143% more. Tensile strength is 110 MPa (16 ksi) vs 85 MPa (12.3 ksi).

Which condition does FabDigit quote by default, H112 or H24?

O is the default 1230A condition in the FabDigit quote flow (neither H112 nor H24). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1230A-H112 or 1230A-H24?

1230A-H24, by a small margin. Both rate poor for machinability — 32/100 against 27/100 for 1230A-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1230A-H112 and 1230A-H24 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.